Scintillation yield of liquid xenon at room temperature

Authors :
Ueshima, K.
Abe, K.
Iida, T.
Ikeda, M.
Kobayashi, K.
Koshio, Y.
Minamino, A.
Miura, M.
Moriyama, S.
Nakahata, M.
Nakajima, Y.
Ogawa, H.
Sekiya, H.
Shiozawa, M.
Suzuki, Y.
Takeda, A.
Takeuchi, Y.
Yamashita, M.
Kaneyuki, K.
Doke, T.
Ebizuka, Y.
Kikuchi, J.
Ota, A.
Suzuki, S.
Takahashi, T.
Hagiwara, H.
Kamei, T.
Miyamoto, K.
Nagase, T.
Nakamura, S.
Ozaki, Y.
Sato, T.
Fukuda, Y.
Nishijima, K.
Sakurai, M.
Maruyama, T.
Motoki, D.
Itow, Y.
Ohsumi, H.
Tasaka, S.
Kim, S. B.
Kim, Y. D.
Lee, J. I.
Moon, S. H.
Source :
Nucl.Instrum.Meth.A594:148-154,2008
Publication Year :
2008

Abstract

The intensity of scintillation light emission from liquid xenon at room temperature was measured. The scintillation light yield at 1 deg. was measured to be 0.64 +/- 0.02 (stat.) +/- 0.06 (sys.) of that at -100 deg. Using the reported light yield at -100 deg. (46 photons/keV), the measured light yield at 1 deg. corresponds to 29 photons/keV. This result shows that liquid xenon scintillator gives high light yield even at room temperature.<br />Comment: 16pages,12figures