Scintillation yield of liquid xenon at room temperature
- Source :
- Nucl.Instrum.Meth.A594:148-154,2008
- Publication Year :
- 2008
-
Abstract
- The intensity of scintillation light emission from liquid xenon at room temperature was measured. The scintillation light yield at 1 deg. was measured to be 0.64 +/- 0.02 (stat.) +/- 0.06 (sys.) of that at -100 deg. Using the reported light yield at -100 deg. (46 photons/keV), the measured light yield at 1 deg. corresponds to 29 photons/keV. This result shows that liquid xenon scintillator gives high light yield even at room temperature.<br />Comment: 16pages,12figures
- Subjects :
- Physics - Instrumentation and Detectors
Subjects
Details
- Database :
- arXiv
- Journal :
- Nucl.Instrum.Meth.A594:148-154,2008
- Publication Type :
- Report
- Accession number :
- edsarx.0803.2888
- Document Type :
- Working Paper
- Full Text :
- https://doi.org/10.1016/j.nima.2008.06.017