Back to Search Start Over

Longitudinal bunch monitoring at the Fermilab Tevatron and Main Injector synchrotrons

Authors :
Thurman-Keup, R.
Bhat, C.
Blokland, W.
Crisp, J.
Eddy, N.
Fellenz, B.
Flora, R.
Hahn, A.
Hansen, S.
Kiper, T.
Para, A.
Pordes, S.
Tollestrup, A. V.
Source :
2011 JINST 6 T10004
Publication Year :
2011

Abstract

The measurement of the longitudinal behavior of the accelerated particle beams at Fermilab is crucial to the optimization and control of the beam and the maximizing of the integrated luminosity for the particle physics experiments. Longitudinal measurements in the Tevatron and Main Injector synchrotrons are based on the analysis of signals from resistive wall current monitors. This article describes the signal processing performed by a 2 GHz-bandwidth oscilloscope together with a computer running a LabVIEW program which calculates the longitudinal beam parameters.

Details

Database :
arXiv
Journal :
2011 JINST 6 T10004
Publication Type :
Report
Accession number :
edsarx.1110.3086
Document Type :
Working Paper
Full Text :
https://doi.org/10.1088/1748-0221/6/10/T10004