Back to Search
Start Over
PMT signal increase using a wavelength shifting paint
- Publication Year :
- 2015
-
Abstract
- We report a 1.65 times increase of the PMT signal and a simple procedure of application of a new wavelength shifting (WLS) paint for PMTs with non-UV-transparent windows. Samples of four different WLS paints, made from hydrocarbon polymers and organic fluors, were tested on a 5-inch PMT (ET 9390KB) using Cherenkov radiation produced in fused silica disks by $^{106}$Ru electrons on a `table-top' setup. The best performing paint was employed on two different types of 5-inch PMTs (ET 9390KB and XP4572B), installed in atmospheric pressure CO$_2$ gas Cherenkov detectors, and tested using GeV electrons.<br />Comment: 6 pages, 8 figures, accepted NIM-A
- Subjects :
- Physics - Instrumentation and Detectors
Nuclear Experiment
Subjects
Details
- Database :
- arXiv
- Publication Type :
- Report
- Accession number :
- edsarx.1502.01772
- Document Type :
- Working Paper
- Full Text :
- https://doi.org/10.1016/j.nima.2015.02.012