Back to Search Start Over

TOF spectroscopy measurement using waveform digitizer

Authors :
Liu, Longxiang
Wang, Hongwei
Ma, Yugang
Cao, Xiguang
Cai, Xiangzhou
Chen, Jingen
Zhang, Guilin
Han, Jianlong
Zhang, Guogiang
Hu, Jifeng
Wang, Xiaohe
Source :
Chinese Physics C Vol. 40, No. 5 (2016) 056202
Publication Year :
2015

Abstract

The photoneutron source (PNS, phase 1), an electron linear accelerator (linac)-based pulsed neutron facility that uses the time-of-flight (TOF) technique, was constructed for the acquisition of nuclear data from the thorium molten salt reactor(TMSR) at the Shanghai Institute of Applied Physics (SINAP). The neutron detector signal, with the information on the pulse arrival time, pulse shape, and pulse height, was recorded by using a waveform digitizer (WFD). By using the pulse height and pulse-shape discrimination (PSD) analysis to identify neutrons and $\gamma$-rays, the neutron TOF spectrum was obtained by employing a simple electronic design, and a new WFD-based DAQ system was developed and tested in this commissioning experiment. The developed DAQ system is characterized by a very high efficiency with respect to millisecond neutron TOF spectroscopy<br />Comment: 5 pages, 7 figures

Details

Database :
arXiv
Journal :
Chinese Physics C Vol. 40, No. 5 (2016) 056202
Publication Type :
Report
Accession number :
edsarx.1508.05708
Document Type :
Working Paper
Full Text :
https://doi.org/10.1088/1674-1137/40/5/056202