Back to Search Start Over

Characterization of Low-Pressure MWPC from 1E3 to 1E5 Pa

Authors :
Wang, Yanfeng
Sun, Zhijia
Wang, Xiaohu
Yi, Han
Jiang, Wei
Fand, Ruirui
Zhou, Liang
He, Yongcheng
Ning, Changjun
He, Yuefeng
Zhao, Yingtan
Sun, Kang
Gao, Keqing
Publication Year :
2021

Abstract

The LPMWPC can be used as the {\Delta}E detector for the low-energy charged particle detection. In order to increase the transmittance, the wires were adopted as the cathode. This work investigated the LPMWPC signal characteristics of this configuration and measured the gas gain with a mixture of 90%Ar and 10% CO2 from 1E3 to 1E5 Pa. From the test, the second pulse after the avalanche signal was observed, which proved to be caused by the ions' drifting near the cathode wire.

Details

Database :
arXiv
Publication Type :
Report
Accession number :
edsarx.2103.09406
Document Type :
Working Paper
Full Text :
https://doi.org/10.1088/1748-0221/16/04/T04003