Back to Search Start Over

Dual-readout calorimetry with homogeneous crystals

Authors :
Hirosky, R.
Anderson, T.
Cummings, G.
Dubnowski, M.
Guinto-Brody, C.
Guo, Y.
Ledovskoy, A.
Levin, D.
Madrid, C.
Martin, C.
Zhu, J.
Publication Year :
2024

Abstract

High resolution calorimetry with state-of-the-art energy resolution performance for both electromagnetic (EM) and hadronic signals can be achieved using the dual-readout (DR) technique, both in a homogeneous scintillating-crystal calorimeter and in a traditional fiber and absorber-based DR hadronic section. We present results from the CalVision consortium studying the collection of Cerenkov and scintillation signals in PbWO$_4$ and BGO crystal samples exposed to 120\,GeV proton beams at the Fermilab Test Beam Facility, including proof-of-principle measurements aimed at demonstrating the identification of a sufficiently large Cerenkov signal in homogeneous scintillating crystals to support dual-readout capability.<br />Comment: 4 pages, 7 figures, Submitted to Proceedings of the contributions to the CALOR2024, EPJ Web of Conferences

Details

Database :
arXiv
Publication Type :
Report
Accession number :
edsarx.2408.11973
Document Type :
Working Paper