Back to Search Start Over

Robotic spine systems: overcoming surgeon experience in pedicle screw accuracy: a prospective study

Authors :
Madhava Pai Kanhangad
Vidyadhara Srinivasa
Balamurugan Thirugnanam
Abhishek Soni
Anjana Kashyap
Alia Vidyadhara
Sharath Kumar Rao
Source :
Asian Spine Journal, Vol 18, Iss 5, Pp 663-672 (2024)
Publication Year :
2024
Publisher :
Korean Spine Society, 2024.

Abstract

Study Design Prospective single-center study. Purpose To compare the accuracy of pedicle screws placed by freehand and under fluoroscopy and robotic assistance with intraoperative image acquisition. Overview of Literature Pedicle screws are the most commonly used spinal anchors owing to their ability to stabilize all three spinal columns. Various techniques such as freehand, fluoroscopy-assisted, and navigation-assisted pedicle screw placements have been used with varying degrees of accuracy. Most studies on robotic-assisted pedicle screw placement have utilized preoperatively acquired computed tomography scans. To our knowledge, this is the only study in the literature that compared freehand with fluoroscopy-guided and robotic-assisted pedicle screw insertion with freehand and fluoroscopy. Methods In this prospective study, a total of 1,120 pedicle screws were placed in the freehand group (n=175), 1,250 in the fluoroscopy-assisted group (n=172), and 1,225 in the robotic-assisted group (n=180). Surgical parameters and screw accuracy were analyzed between the three groups. The preoperative plan overlapped with the postoperative O-arm scan to determine if the screws were executed as planned. Results The frequency of clinically acceptable screw placement (Gertzbein-Robbins grades A and B) in the freehand, fluoroscopy-assisted, and robotic-assisted groups were 97.7%, 98.6%, and 99.34%, respectively. With robotic assistance, an experience-neutralizing effect implied that surgeons with varying levels of experience achieved comparable pedicle screw accuracy, blood loss, O-arm time, robot time, and time per screw. No significant difference in these parameters was found between surgeries commencing before and after 2 PM. No significant differences were noted between the planned and executed screw trajectories in the robotic-assisted group irrespective of surgical experience. Conclusions The third-generation robotic-assisted pedicle screw placement system used in conjunction with intraoperative three-dimensional O-arm imaging consistently demonstrates safe and accurate screw placement with an experience-neutralizing effect.

Details

Language :
English
ISSN :
19761902 and 19767846
Volume :
18
Issue :
5
Database :
Directory of Open Access Journals
Journal :
Asian Spine Journal
Publication Type :
Academic Journal
Accession number :
edsdoj.0527a85d58ac4cba8c31a876ccc22048
Document Type :
article
Full Text :
https://doi.org/10.31616/asj.2024.0191