Back to Search
Start Over
Sine Spin flat detector CT can improve cerebral soft tissue imaging: a retrospective in vivo study
- Source :
- European Radiology Experimental, Vol 8, Iss 1, Pp 1-8 (2024)
- Publication Year :
- 2024
- Publisher :
- SpringerOpen, 2024.
-
Abstract
- Abstract Background Flat detector computed tomography (FDCT) is frequently applied for periinterventional brain imaging within the angiography suite. Novel technical developments such as the Sine Spin FDCT (S-FDCT) may provide an improved cerebral soft tissue contrast. This study investigates the effect of S-FDCT on the differentiation between gray and white matter compared to conventional FDCT (C-FDCT) and multidetector computed tomography (MDCT). Methods A retrospective analysis of a prospectively maintained patient database was performed, including patients who underwent mechanical thrombectomy in our institution and received S-FDCT or C-FDCT as well as MDCT. Differentiation between gray and white matter on the contralateral hemisphere to the ischemic stroke was analyzed quantitatively by contrast-to-noise ratio (CNR) and qualitatively (5-point ordinal scale). Results In a cohort of 109 patients, MDCT demonstrated the best differentiation between gray and white matter compared to both FDCT techniques (p ≤ 0.001). Comparing both generations of FDCT, S-FDCT provided better visibility of the basal ganglia (p = 0.045) and the supratentorial cortex (p = 0.044) compared to C-FDCT both in quantitative and qualitative analyses. Median CNR were as follows: S-FDCT 2.41 (interquartile range [IQR] 1.66–3.21), C-FDCT 0.96 (0.46–1.70), MDCT 3.43 (2.83–4.17). For basal ganglia, median score and IQR were as follows: S-FDCT 2.00 (2.00–3.00), C-FDCT 1.50 (1.00–2.00), MDCT 5.00 (4.00–5.00). Conclusions The novel S-FDCT improves the periinterventional imaging quality of cerebral soft tissue compared to C-FDCT. Thus, it may improve the diagnosis of complications within the angiography suite. MDCT provides the best option for x-ray-based imaging of the brain tissue. Relevance statement Flat detector computed tomography is a promising technique for cerebral soft tissue imaging, while the novel Sine Spin flat detector computed tomography technique improves imaging quality compared to conventional flat detector computed tomography and thus may facilitate periinterventional diagnosis of gray and white matter. Key points • Flat detector computed tomography (FDCT) is frequently applied for periinterventional brain imaging. • The potential of novel Sine Spin FDCT (S-FDCT) is unknown so far. • S-FDCT improves the visibility of cerebral soft tissue compared to conventional FDCT. • Multidetector computed tomography is superior to both FDCT techniques. • S-FDCT may facilitate the evaluation of brain parenchyma within the angiography suite. Graphical Abstract
Details
- Language :
- English
- ISSN :
- 25099280
- Volume :
- 8
- Issue :
- 1
- Database :
- Directory of Open Access Journals
- Journal :
- European Radiology Experimental
- Publication Type :
- Academic Journal
- Accession number :
- edsdoj.060f2ba4d1e43c2b2ee22a4f1be3927
- Document Type :
- article
- Full Text :
- https://doi.org/10.1186/s41747-023-00412-2