Back to Search Start Over

Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process

Authors :
Yuqing WU
Hong ZHOU
Zhijie ZHANG
Zhiquan RONG
Xuemei LI
Zhe SONG
Shuhong ZHAO
Zhongsi YANG
Qun LIU
Lin ZHU
Xiaojuan FAN
Shuli SUN
Wei ZHANG
Jinyu HAN
Haiyan HUANG
Guangcai LIU
Ping CHEN
Xianwu AN
Hui ZHANG
Junxia REN
Xuejing LI
Chenxi YANG
Bo ZHOU
Hui YE
Mingming QIAO
Hua SHEN
Dunzhu GONGJUE
Yunlong ZHUANG
Source :
Zhongguo shuxue zazhi, Vol 37, Iss 3, Pp 275-282 (2024)
Publication Year :
2024
Publisher :
Institute of Blood Transfusion of Chinese Academy of Medical Sciences, 2024.

Abstract

Objective To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. Methods A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. Results The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P

Details

Language :
Chinese
ISSN :
1004549X
Volume :
37
Issue :
3
Database :
Directory of Open Access Journals
Journal :
Zhongguo shuxue zazhi
Publication Type :
Academic Journal
Accession number :
edsdoj.06cff8a30d5446eabfb152249f151d1c
Document Type :
article
Full Text :
https://doi.org/10.13303/j.cjbt.issn.1004%C2%AD549x.2024.03.004&lang=en