Back to Search Start Over

Pharmacokinetics and Safety of Oliceridine Fumarate Injection in Chinese Patients with Chronic Non-Cancer Pain: A Phase I, Single-Ascending-Dose, Open-Label Clinical Trial

Authors :
Ni Y
Huang R
Yang S
Yang XY
Zeng S
Yao A
Huang J
Yang G
Source :
Drug Design, Development and Therapy, Vol Volume 18, Pp 2729-2743 (2024)
Publication Year :
2024
Publisher :
Dove Medical Press, 2024.

Abstract

Yuncheng Ni,1,* Ranglang Huang,2,* Shuang Yang,3 Xiao Yan Yang,3 Shan Zeng,3 An Yao,3 Jie Huang,3 Guoping Yang3,4 1Department of Pain, The Third Xiangya Hospital and Institute of Pain Medicine, Central South University, Changsha, Hunan, 410013, People’s Republic of China; 2Department of General Surgery, The Third Xiangya Hospital, Central South University, Changsha, Hunan, 410013, People’s Republic of China; 3Center of Clinical Pharmacology, The Third Xiangya Hospital, Central South University, Changsha, Hunan, 410013, People’s Republic of China; 4Xiangya School of Pharmaceutical Sciences, Central South University, Changsha, Hunan, 410013, People’s Republic of China*These authors contributed equally to this workCorrespondence: Jie Huang; Guoping Yang, Email cellahuang1988@163.com; ygp9880@126.comBackground: Oliceridine is a novel G protein‐biased ligand μ-opioid receptor agonist. This study aimed to assess the pharmacokinetics and safety profile of single-ascending doses of oliceridine fumarate injection in Chinese patients with chronic non-cancer pain.Methods: Conducted as a single-center, open-label trial, this study administered single doses of 0.75, 1.5, and 3.0 mg to 32 adult participants. The trial was conducted in two parts. First, we conducted a preliminary test comprising the administration of a single dose of 0.75mg to 2 participants. Then, we conducted the main trial involving intravenous administration of escalating doses of oliceridine fumarate (0.75 to 3 mg) to 30 participants. Pharmacokinetic (PK) parameters were derived using non-compartmental analysis. Additionally, the safety evaluation encompassed the monitoring of adverse events (AEs).Results: 32 participants were included in the PK and safety analyses. Following a 2-min intravenous infusion of oliceridine fumarate injection (0.75, 1.5, or 3 mg), Cmax and Tmax ranged from 51.293 to 81.914 ng/mL and 0.034 to 0.083 h, respectively. AUC0-t and half-life (t1/2) increased more than proportionally with dosage (1.85– 2.084 h). Treatment emergent adverse events (TEAEs) were found to be consistent with the commonly reported adverse effects of opioids, both post-administration and as documented in the original trials conducted in the United States. Critically, no serious adverse events were observed.Conclusion: Oliceridine demonstrated comparable PK parameters and a consistent PK profile in the Chinese population, in line with the PK results observed in the original trials conducted in the United States. Oliceridine was safe and well tolerated in Chinese patients with chronic non-cancer pain at doses ranging from 0.75 mg to 3.0 mg.Trial Registration: The trial is registered at chictr.org.cn (ChiCTR2100047180).Keywords: pharmacokinetics, oliceridine, chronic pain, G-protein-biased ligand, phase I trial

Details

Language :
English
ISSN :
11778881
Volume :
ume 18
Database :
Directory of Open Access Journals
Journal :
Drug Design, Development and Therapy
Publication Type :
Academic Journal
Accession number :
edsdoj.0731ec00cbf04a19877b4c875eb00905
Document Type :
article