Large-field high-resolution X-ray AKB microscope for measuring hydrodynamic instabilities at the SG-III prototype laser facility

Authors :
Liang Chen
Pin Yang
Jie Xu
Baozhong Mu
Wenjie Li
Xinye Xu
Mingtao Li
Jinbo Li
Xin Wang
Xing Zhang
Feng Wang
Zhanshan Wang
Dong Yang
Source :
Scientific Reports, Vol 14, Iss 1, Pp 1-10 (2024)
Publication Year :
2024
Publisher :
Nature Portfolio, 2024.

Abstract

Abstract X-ray imaging with a large field of view (FOV) and high resolution is extremely important for Rayleigh–Taylor instability measurement with a small amplitude and high spatial frequency in laser inertial confinement fusion. We developed an advanced Kirkpatrick–Baez (AKB) microscope based on the quadratic-aberration theory to realize a large FOV and high resolution. This microscope was assembled and tested in a laboratory, and it was then successfully applied for imaging the hydrodynamic instability of a perturbation target in implosion experiments at the Shenguang-III prototype laser facility. Imaging results demonstrate that the AKB microscope can achieve an optimal resolution of ~ 0.53 μm and ~ 0.40 μm and a spatial resolution of

Details

Language :
English
ISSN :
20452322
Volume :
14
Issue :
1
Database :
Directory of Open Access Journals
Journal :
Scientific Reports
Publication Type :
Academic Journal
Accession number :
edsdoj.08d1272c95744feda281b305621e67f6
Document Type :
article
Full Text :
https://doi.org/10.1038/s41598-024-78989-w