Back to Search Start Over

A new reservoir-based CPAP with low oxygen consumption: the Bag-CPAP

Authors :
Eloïse de Beaufort
Guillaume Carteaux
François Morin
Arnaud Lesimple
Anne-Fleur Haudebourg
Emeline Fresnel
Damien Duval
Alexandre Broc
Alain Mercat
Laurent Brochard
Dominique Savary
François Beloncle
Armand Mekontso Dessap
Jean-Christophe Richard
Source :
Critical Care, Vol 27, Iss 1, Pp 1-11 (2023)
Publication Year :
2023
Publisher :
BMC, 2023.

Abstract

Abstract Background Several noninvasive ventilatory supports rely in their design on high oxygen consumption which may precipitate oxygen shortage, as experienced during the COVID-19 pandemic. In this bench-to-bedside study, we assessed the performance of a new continuous positive airway pressure (CPAP) device integrating a large reservoir (“Bag-CPAP”) designed to minimize oxygen consumption, and compared it with other CPAP devices. Methods First, a bench study compared the performances of Bag-CPAP and four CPAP devices with an intensive care unit ventilator. Two FiO2 targets (40–60% and 80–100%) at a predefined positive end expiratory pressure (PEEP) level between 5 and 10 cm H2O were tested and fraction of inspired oxygen (FiO2) and oxygen consumption were measured. Device-imposed work of breathing (WOB) was also evaluated. Second, an observational clinical study evaluated the new CPAP in 20 adult patients with acute respiratory failure in two hospitals in France. Actual FiO2, PEEP, peripheral oxygen saturation, respiratory rate, and dyspnea score were assessed. Results All six systems tested in the bench study reached the minimal FiO2 target of 40% and four reached at least 80% FiO2 while maintaining PEEP in the predefined range. Device-delivered FiO2/consumed oxygen ratio was the highest with the new reservoir-based CPAP irrespective of FiO2 target. WOB induced by the device was higher with Bag-CPAP. In the clinical study, Bag-CPAP was well tolerated and could reach high (> 90%) and moderate (> 50%) FiO2 with an oxygen flow rate of 15 [15–16] and 8 [7–9] L/min, respectively. Dyspnea score improved significantly after introduction of Bag-CPAP, and SpO2 increased. Conclusions In vitro, Bag-CPAP exhibited the highest oxygen saving properties albeit had increased WOB. It was well accepted clinically and reduced dyspnea. Bag-CPAP may be useful to treat patients with acute respiratory failure in the field, especially when facing constraints in oxygen delivery.

Details

Language :
English
ISSN :
13648535
Volume :
27
Issue :
1
Database :
Directory of Open Access Journals
Journal :
Critical Care
Publication Type :
Academic Journal
Accession number :
edsdoj.093ec1e7906a473ca7ddb8fa1afdbce0
Document Type :
article
Full Text :
https://doi.org/10.1186/s13054-023-04542-2