Back to Search Start Over

A Novel Antibacterial Membrane Electrode Based on Bacterial Cellulose/Polyaniline/AgNO3 Composite for Bio-Potential Signal Monitoring

Authors :
Nannan Zhang
Lina Yue
Yajie Xie
Oluwarotimi William Samuel
Olatunji Mumini Omisore
Weihua Pei
Xiao Xing
Chuang Lin
Yudong Zheng
Lei Wang
Source :
IEEE Journal of Translational Engineering in Health and Medicine, Vol 6, Pp 1-10 (2018)
Publication Year :
2018
Publisher :
IEEE, 2018.

Abstract

We propose a flexible, dry, and antibacterial electrode with a low and stable skin electrode contact impedance for bio-potential signal monitoring. We fabricated a bacterial cellulose/polyaniline/AgNO3 nanocomposite membrane (BC/PANI/AgNO3) and used it for bio-potential signal monitoring. The bacterial cellulose (BC) provides a 3-D nanoporous network structure, and it was used as a substrate material in the BC/PANI/AgNO3 nanocomposite membrane. Polyaniline (PANI) and AgNO3, acting as conductive and antibacterial components, respectively, were polymerized and deposited on the surfaces of BC nanofibers to produce uniform thin film membrane with flexible, antibacterial, and conductive properties. Various measurements were conducted, in terms of antibacterial activity, skin electrode contact impedance, and qualitative analysis of ECG signal recordings. The BC/PANI/AgNO3 membrane revealed 100% antibacterial activities against both the Staphylococcus aureus and Escherichia coli bacteria. The skin electrode contact impedance of the proposed BC/PANI/AgNO3 electrode is lower than that of the Ag/AgCl gel electrode, with the same active area. In addition, the electrocardiogram (ECG) signals acquired with the proposed electrodes have stable characteristic waveforms, and they are not contaminated by noise. The waveform fidelity of the BC/PANI/AgNO3 membrane electrodes over 800 ECG cardiac cycles is 99.49%, and after the electrodes were worn for 24 hours, a fidelity of 98.40% was recorded over the same number of cardiac cycles. With the low and stable skin electrode contact impedance, the proposed dry BC/PANI/AgNO3 membrane electrode provided high fidelity for ECG signal recordings, thus offering a potential approach for bio-potential signal monitoring. With the above benefits, the novel flexible and dry BC/PANI/AgNO3 electrode has a significant antibacterial. Most of all, it is the first research to develop antibacterial in the electrode design.

Details

Language :
English
ISSN :
21682372
Volume :
6
Database :
Directory of Open Access Journals
Journal :
IEEE Journal of Translational Engineering in Health and Medicine
Publication Type :
Academic Journal
Accession number :
edsdoj.0c6c0a76e9b4f66b37ca351e481addf
Document Type :
article
Full Text :
https://doi.org/10.1109/JTEHM.2018.2863388