Back to Search Start Over

Ventricular arrhythmia burden in patients with implantable cardioverter defibrillator and remote patient monitoring during different time intervals of the COVID-19 pandemic

Authors :
Christian Hauck
Andreas Schober
Alexander Schober
Sabine Fredersdorf
Ute Hubauer
Lars Maier
Andreas Keyser
Moritz Huttelmaier
Thomas Fischer
Carsten Jungbauer
Ekrem Ücer
Source :
European Journal of Medical Research, Vol 27, Iss 1, Pp 1-9 (2022)
Publication Year :
2022
Publisher :
BMC, 2022.

Abstract

Abstract Purpose The current study investigated whether the changes in patient care in times of the COVID-19 pandemic, especially the reduction of in-person visits, would result in a deterioration of the arrhythmic and clinical condition of patients with an implantable cardioverter defibrillator (ICD) and remote patient monitoring. Methods Data were obtained from a local ICD registry. 140 patients who received ICD implantation at our department and had remote patient monitoring were included. The number of patients with ventricular arrhythmias, appropriate ICD therapy, the number of visits to our outpatient clinic and hospitalization due to acute coronary syndrome, stroke or heart failure were compared during three time intervals of the COVID-19 pandemic (first (LD1) and second (LD2) national lockdown in Germany and the time after the first lockdown (postLD1)) and a time interval 1 year before the pandemic began (preCOV). Each time interval was 49 days long. Results Patients had significantly fewer visits to our outpatient clinic during LD1 (n = 13), postLD1 (n = 22) and LD2 (n = 23) compared to the time interval before the pandemic (n = 43, each p ≤ 0.05). The number of patients with sustained ventricular arrhythmias, appropriate ICD therapy and clinical events showed no significant difference during the time intervals of the COVID-19 pandemic and the time interval 1 year prior. Conclusions The lockdown measures necessary to reduce the risk of infection during the COVID-19 pandemic, led to a reduction of in-person patient visits, but did not result in a deterioration of the arrhythmic and clinical condition of ICD patients with remote patient monitoring.

Details

Language :
English
ISSN :
2047783X
Volume :
27
Issue :
1
Database :
Directory of Open Access Journals
Journal :
European Journal of Medical Research
Publication Type :
Academic Journal
Accession number :
edsdoj.0f44dd493d03445580a8e3bf645fa20b
Document Type :
article
Full Text :
https://doi.org/10.1186/s40001-022-00867-w