Sorry, I don't understand your search. ×
Back to Search Start Over

One‐year results following PASCAL‐based or MitraClip‐based mitral valve transcatheter edge‐to‐edge repair

Authors :
Nicolas A. Geis
Philipp Schlegel
Markus B. Heckmann
Hugo A. Katus
Norbert Frey
Patricia Crespo López
Philip W.J. Raake
Source :
ESC Heart Failure, Vol 9, Iss 2, Pp 853-865 (2022)
Publication Year :
2022
Publisher :
Wiley, 2022.

Abstract

Abstract Aims Mitral valve transcatheter edge‐to‐edge repair (TEER) has been established as a suitable alternative to mitral valve surgery in patients with severe mitral regurgitation (MR) and high surgical risk. The PASCAL system represents a novel device, potentially augmenting the toolkit for TEER. The aim of this study was to assess and compare short and 1 year safety and efficacy of the PASCAL and MitraClip systems for TEER. Methods and results Procedural, short, and 1 year outcomes of a 1:2 propensity‐matched cohort including 41 PASCAL and 82 MitraClip cases were investigated. Matching was based on clinical, laboratory, echocardiographic, and functional characteristics. The primary endpoints assessed were procedural success [as defined by the Mitral Valve Academy Research Consortium (MVARC)], residual MR, functional class, and a composite endpoint comprising death, heart failure hospitalization, and mitral valve re‐intervention. We found for the PASCAL and the matched MitraClip cohort no significant differences in MVARC defined technical (90.2% vs. 95.1%, P = 0.44), device (90.2% vs. 89.0%, P = 1.0), or procedural (87.8% vs. 80.5%, P = 0.45) success rates. Accordingly, the overall MR reduction and improvement in New York Heart Association (NYHA) class were comparable (1 year follow‐up: MR ≤ 2 95% vs. 93.6%, P = 1.0; NYHA ≤ 2 57.1% vs. 66.7%, P = 0.59). The composite outcome revealed no statistically significant difference between both devices (1 year follow‐up: 31.7% vs. 37.8%, P = 0.55). Interestingly, we found at both short and 1 year follow‐up a significantly higher rate of patients with none or trace MR in the PASCAL‐treated cohort (short follow‐up: 17.9% vs. 0%, P = 0.0081; 1 year follow‐up: 25% vs. 0%, P = 0.0016). Conversely, the rate of aborted device implantations due to an elevated transmitral gradient was higher in PASCAL interventions (9.8% vs. 1.2%, P = 0.04). Conclusions Transcatheter edge‐to‐edge repair using the PASCAL or MitraClip device results in favourable and comparable outcomes regarding safety, efficacy, and clinical improvement after 1 year.

Details

Language :
English
ISSN :
20555822
Volume :
9
Issue :
2
Database :
Directory of Open Access Journals
Journal :
ESC Heart Failure
Publication Type :
Academic Journal
Accession number :
edsdoj.10cc5b3d7a63488498c12301140acbcd
Document Type :
article
Full Text :
https://doi.org/10.1002/ehf2.13849