Analysis of the Effects of Back-stayed Arrangement on the Mechanical Properties of Corbel Shelf
- Source :
- MATEC Web of Conferences, Vol 51, p 03005 (2016)
- Publication Year :
- 2016
- Publisher :
- EDP Sciences, 2016.
-
Abstract
- With AS/RS corbel shelf as research object, the orthogonal experiment was designed, which is composed of 21 groups of schemes and 3 kinds of load conditions. By using the Rack Computer-Aided FEA System based on SAP84, this paper presents the effects of grounding back-stayed and the ground floor height of back-stayed on the strength, rigidity and stability of corbel shelf under normal load, horizontal load in X direction and horizontal load in Y direction. The results show that in all conditions, grounding back-stayed improves the strength and stability of column, and the strength and stability of corbel shelf will be enhanced with the decrease of the ground floor height of back-stayed. This research provides a theoretical basis for the analysis and design of corbel shelf.
- Subjects :
- Engineering (General). Civil engineering (General)
TA1-2040
Subjects
Details
- Language :
- English, French
- ISSN :
- 2261236X
- Volume :
- 51
- Database :
- Directory of Open Access Journals
- Journal :
- MATEC Web of Conferences
- Publication Type :
- Academic Journal
- Accession number :
- edsdoj.1258fc67a248fe822cfb08979bf52c
- Document Type :
- article
- Full Text :
- https://doi.org/10.1051/matecconf/20165103005