Back to Search Start Over

Novel quantification of the regional strain distribution in the anterior cruciate ligament in response to simulated loading using micro‐CT imaging

Authors :
Alexandra M. Blokker
Ryan Wood
Jaques C. Milner
David W. Holdsworth
Timothy A. Burkhart
Alan Getgood
Source :
Journal of Experimental Orthopaedics, Vol 8, Iss 1, Pp n/a-n/a (2021)
Publication Year :
2021
Publisher :
Wiley, 2021.

Abstract

Abstract Purpose A large percentage of anterior cruciate ligament (ACL) surgical reconstructions experience sub‐optimal outcomes within 2 years. A potential factor contributing to poor outcomes is an incomplete understanding of micro‐level, regional ACL biomechanics. This research aimed to demonstrate a minimally invasive method that uses micro‐CT imaging to quantify regional ACL strains under clinically relevant joint loading. Methods A pattern of 0.8 mm diameter zirconium dioxide beads were arthroscopically inserted into four regions of the ACL of four cadaveric knee specimens (mean [SD] age = 59 [9] years). A custom micro‐CT compatible joint motion simulator then applied clinically relevant joint loading conditions, while an image was acquired at each condition. From the resulting images, strains within each region were calculated using the centroid coordinates of each tissue‐embedded bead. Strain repeatability was assessed using the mean intra‐specimen standard deviation across repeated load applications. A one‐way repeated measures ANOVA (α = 0.05) was used to determine regional strain variations. Results The mean intra‐specimen standard deviation across repeated load application was ±0.003 strain for all specimens. No statistically significant differences were found between tissue regions, although medium and large effect sizes (0.095–0.450) suggest that these differences may be clinically relevant. Conclusions The method presented here demonstrates a minimally invasive measurement of regional ACL strain under clinically relevant joint loads using micro‐CT imaging. The strain measurements demonstrated excellent reliability across the five repeated load applications and suggest a non‐homogenous distribution of strain through the ACL.

Details

Language :
English
ISSN :
21971153
Volume :
8
Issue :
1
Database :
Directory of Open Access Journals
Journal :
Journal of Experimental Orthopaedics
Publication Type :
Academic Journal
Accession number :
edsdoj.149bef4641aa47fcad6c0023677d312e
Document Type :
article
Full Text :
https://doi.org/10.1186/s40634-021-00416-0