Back to Search Start Over

Water-Spray-Cooled Quasi-Isothermal Compression Method: Water-Spray Flow Improvement

Authors :
Guanwei Jia
Xuanwei Nian
Weiqing Xu
Yan Shi
Maolin Cai
Source :
Entropy, Vol 23, Iss 6, p 724 (2021)
Publication Year :
2021
Publisher :
MDPI AG, 2021.

Abstract

Water-spray-cooled quasi-isothermal compressed air energy storage aims to avoid heat energy losses from advanced adiabatic compressed-air energy storage (AA-CAES). The compression efficiency increases with injection water spray. However, the energy-generated water spray cannot be ignored. As the air pressure increases, the work done by the piston and the work converted into heat rise gradually in the compression process. Accordingly, the flow rate of the water needed for heat transfer is not a constant with respect to time. To match the rising compression heat, a time sequence of water-spray flow rate is constructed, and the algorithm is designed. Real-time water-spray flow rate is calculated according to the difference between the compression power and heat-transfer power. Compared with the uniform flow rate of water spray, energy consumption from the improved flow rate is reduced.

Details

Language :
English
ISSN :
10994300
Volume :
23
Issue :
6
Database :
Directory of Open Access Journals
Journal :
Entropy
Publication Type :
Academic Journal
Accession number :
edsdoj.18cb54826a9a4a08b49dada2768df750
Document Type :
article
Full Text :
https://doi.org/10.3390/e23060724