Back to Search Start Over

Measurements of the ionization efficiency of protons in methane

Authors :
L. Balogh
C. Beaufort
A. Brossard
J.-F. Caron
M. Chapellier
J.-M. Coquillat
E. C. Corcoran
S. Crawford
A. Dastgheibi-Fard
Y. Deng
K. Dering
D. Durnford
C. Garrah
G. Gerbier
I. Giomataris
G. Giroux
P. Gorel
M. Gros
P. Gros
O. Guillaudin
E. W. Hoppe
I. Katsioulas
F. Kelly
P. Knights
S. Langrock
P. Lautridou
I. Manthos
R. D. Martin
J. Matthews
J.-P. Mols
J.-F. Muraz
T. Neep
K. Nikolopoulos
P. O’Brien
M.-C. Piro
D. Santos
G. Savvidis
I. Savvidis
F. A. Vazquez de Sola Fernandez
M. Vidal
R. Ward
M. Zampaolo
NEWS-G Collaboration
Source :
European Physical Journal C: Particles and Fields, Vol 82, Iss 12, Pp 1-10 (2022)
Publication Year :
2022
Publisher :
SpringerOpen, 2022.

Abstract

Abstract The amount of energy released by a nuclear recoil ionizing the atoms of the active volume of detection appears “quenched” compared to an electron of the same kinetic energy. This different behavior in ionization between electrons and nuclei is described by the Ionization Quenching Factor (IQF) and it plays a crucial role in direct dark matter searches. For low kinetic energies (below $$50~\textrm{keV}$$ 50 keV ), IQF measurements deviate significantly from common models used for theoretical predictions and simulations. We report measurements of the IQF for proton, an appropriate target for searches of Dark Matter candidates with a mass of approximately $$1~\textrm{GeV}$$ 1 GeV , with kinetic energies in between $$2~\textrm{keV}$$ 2 keV and $$13~\textrm{keV}$$ 13 keV in $$100~\textrm{mbar}$$ 100 mbar of methane. We used the Comimac facility in order to produce the motion of nuclei and electrons of controlled kinetic energy in the active volume, and a NEWS-G SPC to measure the deposited energy. The Comimac electrons are used as a reference to calibrate the detector with 7 energy points. A detailed study of systematic effects led to the final results well fitted by $$\textrm{IQF}~(E_K)= E_K^\alpha ~/~(\beta + E_K^\alpha )$$ IQF ( E K ) = E K α / ( β + E K α ) with $$\alpha = 0.70\pm 0.08$$ α = 0.70 ± 0.08 and $$\beta = 1.32\pm 0.17$$ β = 1.32 ± 0.17 . In agreement with some previous works in other gas mixtures, we measured less ionization energy than predicted from SRIM simulations, the difference reaching $$33\%$$ 33 % at $$2~\textrm{keV}$$ 2 keV .

Details

Language :
English
ISSN :
14346052
Volume :
82
Issue :
12
Database :
Directory of Open Access Journals
Journal :
European Physical Journal C: Particles and Fields
Publication Type :
Academic Journal
Accession number :
edsdoj.210f1162a24447f6b7eb484def335cfc
Document Type :
article
Full Text :
https://doi.org/10.1140/epjc/s10052-022-11063-9