Back to Search Start Over

Electrophysiology lab efficiency using cryoballoon for pulmonary vein isolation in Latin America: A sub-analysis of the Cryo Global Registry Study

Authors :
Armando Pérez-Silva
Rodrigo Isa-Param
Juan F Agudelo-Uribe
Alex Pacheco-Bouthillier
Reece Holbrook
Daniela Paredes-Fernández
Kyla Jones
Juan Tellez
Thomas R Holmes
Alicia Sale
Nicolás Martinenghi
Source :
Medwave, Vol 24, Iss 08, Pp e2918-e2918 (2024)
Publication Year :
2024
Publisher :
Medwave Estudios Limitada, 2024.

Abstract

Objective Cryoballoon ablation for pulmonary vein isolation is a time-efficient procedure that can alleviate stress on electrophysiology lab resources. This analysis modeled the impact of cryoballoon ablation on electrophysiology lab operation using data from Latin America. Methods Data from centers in Argentina, Mexico, Colombia, and Chile of the Cryo Global Registry were used as inputs for an electrophysiology lab efficiency simulation model. The model used the assumption that either two (today’s electrophysiology lab operations) or three (including electrophysiology lab operational changes) cryoballoon ablation procedures could be performed per day. The endpoints were the percentage of days that resulted in 1) overtime and 2) time left for an extra non-ablation electrophysiology procedure. Results Data from a total of 232 procedures from six Latin American centers were included in the analysis. The average electrophysiology lab occupancy time for all procedures in Latin America was 132 ± 62 minutes. In the Current Scenario (two procedures per day), 7.4% of simulated days resulted in overtime, and 81.4% had enough time for an extra electrophysiology procedure. In the Enhanced Productivity Scenario (three procedures per day), 16.4% of days used overtime, while 67.4% allowed time for an extra non-ablation electrophysiology procedure. Conclusions Using real-world, Latin American-specific data, we found that with operational changes, three ablation procedures could feasibly be performed daily, leaving time for an extra electrophysiology procedure on more than half of days. Thus, use of cryoballoon ablation is an effective tool to enhance electrophysiology lab efficiency in resource-constrained regions such as Latin America.

Details

Language :
English, Spanish; Castilian
ISSN :
07176384
Volume :
24
Issue :
08
Database :
Directory of Open Access Journals
Journal :
Medwave
Publication Type :
Academic Journal
Accession number :
edsdoj.22d6b67d038949f4a2d3908026f25b10
Document Type :
article
Full Text :
https://doi.org/10.5867/medwave.2024.08.2918