Back to Search Start Over

Effect of a mattress on lumbar spine alignment in supine position in healthy subjects: an MRI study

Authors :
Jacopo Antonino Vitale
Stefano Borghi
Tito Bassani
Carmelo Messina
Luca Maria Sconfienza
Fabio Galbusera
Source :
European Radiology Experimental, Vol 7, Iss 1, Pp 1-9 (2023)
Publication Year :
2023
Publisher :
SpringerOpen, 2023.

Abstract

Abstract Background Humans should sleep for about a third of their lifetime and the choice of the mattress is very important from a quality-of-life perspective. Therefore, the primary aim of this study was to assess the changes of lumbar angles, evaluated in a supine position using magnetic resonance imaging (MRI), on a mattress versus a rigid surface. Methods Twenty healthy subjects (10 females, 10 males), aged 32.3 ± 6.5 (mean ± standard deviation), with body mass index 22.4 ± 2.9, completed three evaluations: (i) spine MRI in supine position on a mattress (MAT); (ii) spine MRI in supine position on rigid surface (CON); and (iii) biplanar radiographic imaging in standing position. The following indexes were calculated for both MAT and CON: lumbar lordosis angles L1–L5, L1–S1, L5–S1, and the sacral slope (SS). Further, pelvic incidence (PI) was calculated from the biplanar radiographic images. Results Main findings were (i) L1–L5 and SS were greater in MAT than CON (L1:L5: +2.9°; SS: +2.0°); (ii) L5–S1 was lower in MAT than CON (−1.6°); (iii) L1–S1 was greater in MAT than CON only for male subjects (+2.0°); (iv) significant and positive correlations between PI and L1–L5, L1–S1 and SS were observed in both CON and MAT. Conclusions The use of a mattress determined small but statistically significant changes in lumbar angles. Relevance statement The use of a mattress determines small but statistically significant changes in radiological angles describing the sagittal alignment of the lumbar spine when lying in the supine position. Key points • Lordosis angle L1–L5 was greater in MAT than in CON condition (+2.9°). • Sacral slope was greater in MAT than in CON condition (+2.0°). • Lordosis angle L5–S1 was lower in MAT than in CON condition (−1.6°). Graphical Abstract

Details

Language :
English
ISSN :
25099280
Volume :
7
Issue :
1
Database :
Directory of Open Access Journals
Journal :
European Radiology Experimental
Publication Type :
Academic Journal
Accession number :
edsdoj.293c850a33bd40a0aa826931cd525a47
Document Type :
article
Full Text :
https://doi.org/10.1186/s41747-023-00361-w