Back to Search Start Over

Efficacy of internal fixation with mini plate and internal fixation with hollow screw for Regan-Morrey type II and III ulna coronoid fractures

Authors :
Hong-Wei Chen
Hong-Hui He
Bin-Li Gao
Source :
BMC Musculoskeletal Disorders, Vol 19, Iss 1, Pp 1-7 (2018)
Publication Year :
2018
Publisher :
BMC, 2018.

Abstract

Abstract Background Ulna coronoid fracture is a complicated injury and occurred in the coronal plane. Undeniably, there is no universally accepted approach for treating ulna coronoid fractures. Therefore, this study aimed at exploring the efficacy of different surgical treatments for Regan-Morrey type II and III ulna coronoid fractures. Methods A total of 164 patients with ulna coronoid fractures were admitted and treated in department of orthopedics at Yiwu Central Hospital, the Affiliated Yiwu Hospital of Wenzhou Medical University for retrospective analysis. The baseline features (age, gender, time from injury to surgery and so on) before the surgery and different conditions during the surgery were compared. Following that, the Visual Analogue Scale (VAS) pain score was employed to evaluate the severity of preoperative and postoperative pain experienced by the patients in each group. Afterwards, Broberg and Morrey elbow score was used to evaluate elbow joint function and surgical effect of the patients. Lastly, the postoperative recovery and complications were compared. Results It was firstly observed that internal fixation with mini plate and hollow screw compelled to lower average operation time and blood loss than Kirschner wire and steel wire suture. Next, the severity of postoperative pain was lessened in comparison with preoperative pain. Afterwards, mini plate and hollow screw improved elbow joint function more notable than Kirschner wire and steel wire suture, and Kirschner wire and steel wire suture resulted in higher incidence of complications and worse postoperative recovery. Conclusion Collectively, this study clarified that for the treatment of Regan-Morrey type II and III ulna coronoid fractures, internal fixation with mini plate and hollow screw has an overall superior surgical effect than internal fixation with Kirschner wire and steel wire suture.

Details

Language :
English
ISSN :
14712474
Volume :
19
Issue :
1
Database :
Directory of Open Access Journals
Journal :
BMC Musculoskeletal Disorders
Publication Type :
Academic Journal
Accession number :
edsdoj.2af13dfd245940849b8c8994a662b471
Document Type :
article
Full Text :
https://doi.org/10.1186/s12891-018-2117-4