Abstract

Wood's vulnerability to combustion compromises its structural integrity during fire incidents, primarily due to a decrease in effective cross-section area. This study investigates the efficacy of impregnation Chinese fir lumbers with a 30 % concentration of borate-containing phenol–formaldehyde resin, coupled with a 30 % compression treatment, employed as exposed side laminas for glulam columns. Full-scale glulam columns underwent one-sided fire exposure to assess the impact of the modified laminas. Results reveal a significant increase in column ignition time by 55–195 s, due to the combined treatment. The charring rate of columns containing a single modified lamina in the fire-side zone decreased from 0.733 to 0.552 mm/min after 60 min of fire exposure and further reduced from 0.503 to 0.351 mm/min after 120 min fire exposure for double modified laminas. Compared to the control, glulam columns containing a single modified lamina showcased a 31 % increase in residual bearing capacity at 60 min fire exposure duration and a 62.1 % increase at 120 min with double modified laminas. ABAQUS simulation results corroborated experimental findings, highlighting substantial enhancement in fire resistance achieved due to the modified laminas in the fire-side zone.

Details

Language :
English
ISSN :
2214157X
Volume :
60
Issue :
104639-
Database :
Directory of Open Access Journals
Journal :
Case Studies in Thermal Engineering
Publication Type :
Academic Journal
Accession number :
edsdoj.2beed5999b4c4324ba339c8a5c92d237
Document Type :
article
Full Text :
https://doi.org/10.1016/j.csite.2024.104639