Application of Novel Intraoperative Neuromonitoring System Using an Endotracheal Tube With Pressure Sensor During Thyroid Surgery: A Porcine Model Study
- Source :
- Clinical and Experimental Otorhinolaryngology, Vol 13, Iss 3, Pp 291-298 (2020)
- Publication Year :
- 2020
- Publisher :
- Korean Society of Otorhinolaryngology-Head and Neck Surgery, 2020.
-
Abstract
- Objectives The loss of signal during intraoperative neuromonitoring (IONM) using electromyography (EMG) in thyroidectomy is one of the biggest problems. We have developed a novel IONM system with an endotracheal tube (ETT) with an attached pressure sensor instead of EMG to detect laryngeal twitching. The aim of the present study was to investigate the feasibility and reliability of this novel IONM system using an ETT with pressure sensor during thyroidectomy in a porcine model. Methods We developed an ETT-attached pressure sensor that uses the piezoelectric effect to measure laryngeal muscle twitching. Stimulus thresholds, amplitude, and latency of laryngeal twitching evaluated using the pressure sensor were compared to those measured using transcartilage needle EMG. The measured amplitude changes by EMG and the pressure sensor during recurrent laryngeal nerve (RLN) traction injury were compared. Results No significant differences in stimulus threshold intensity between EMG and the pressure sensor were observed. The EMG amplitude detected at 0.3 mA, increased with increasing stimulus intensity. When the stimulus was more than 1.0 mA, the amplitude showed a plateau. In a RLN traction injury experiment, the EMG amplitude did not recover even 20 minutes after stopping RLN traction. However, the pressure sensor showed a mostly recovery. Conclusion The change in amplitude due to stimulation of the pressure sensor showed a pattern similar to EMG. Pressure sensors can be feasibly and reliably used for RLN traction injury prediction, RLN identification, and preservation through the detection of laryngeal muscle twitching. Our novel IONM system that uses an ETT with an attached pressure sensor to measure the change of surface pressure can be an alternative to EMG in the future.
Details
- Language :
- English
- ISSN :
- 19768710 and 20050720
- Volume :
- 13
- Issue :
- 3
- Database :
- Directory of Open Access Journals
- Journal :
- Clinical and Experimental Otorhinolaryngology
- Publication Type :
- Academic Journal
- Accession number :
- edsdoj.2c1a73bfee4f4452b8ea6500869dcf3b
- Document Type :
- article
- Full Text :
- https://doi.org/10.21053/ceo.2019.01249