Back to Search Start Over

Comparative analysis of MOSESTM technology versus novel thulium fiber laser (TFL) for transurethral enucleation of the prostate: A single-institutional study

Authors :
Hazem Elmansy
Amr Hodhod
Ahmed Elshafei
Yasser A. Noureldin
Vahid Mehrnoush
Ahmed S. Zakaria
Ruba Abdul Hadi
Moustafa Fathy
Loay Abbas
Ahmed Kotb
Walid Shahrour
Source :
Archivio Italiano di Urologia e Andrologia, Vol 94, Iss 2 (2022)
Publication Year :
2022
Publisher :
PAGEPress Publications, 2022.

Abstract

Introduction: Novel laser technologies have been developed for the minimally invasive surgical management of benign prostatic hyperplasia (BPH). The objective of this study was to assess the safety and efficacy of MOSESTM technology versus the thulium fiber laser (TFL) in patients with BPH undergoing transurethral enucleation of the prostate. Methods: We conducted a retrospective review of prospectively collected data of eighty-two patients who underwent transurethral enucleation of the prostate using MOSESTM or TFL technologies from August 2020 to September 2021. Preoperative and intraoperative parameters, in addition to postoperative outcomes, were collected and analyzed. Results: Twenty patients underwent transurethral enucleation of the prostate with TFL, while 62 had MOSESTM HoLEP. No statistically significant difference in preoperative characteristics was observed between the groups. Patients in the TFL group had longer median enucleation, hemostasis, and morcellation times (p < 0.001) than those in the MOSESTM cohort. The longer morcellation time of TFL is mostly related to less visibility. The postoperative outcomes IPSS, QoL, Qmax, and post void residual (PVR), were comparable between the groups at 1, 3 and 6 months. The incidence of urge urinary incontinence (p = 0.79), stress urinary incontinence (p = 0.97), and hospital readmission rates (p = 0.1) were comparable between the two groups. Conclusions: A satisfactory safety and efficacy profile with comparable postoperative outcomes was demonstrated for both techniques; though, MOSESTM technology was superior to TFL in terms of shorter overall operative time.

Details

Language :
English
ISSN :
11243562 and 22824197
Volume :
94
Issue :
2
Database :
Directory of Open Access Journals
Journal :
Archivio Italiano di Urologia e Andrologia
Publication Type :
Academic Journal
Accession number :
edsdoj.2d32f1c1418439ab614c613c0ca69d9
Document Type :
article
Full Text :
https://doi.org/10.4081/aiua.2022.2.180