Back to Search Start Over

Detection of clenbuterol hydrochloride residuals in pork liver using a customized surface plasmon resonance bioanalyzer.

Authors :
Jiandong Hu
Ruipeng Chen
Shun Wang
Tingting Wang
Yuanyuan Zhao
Jianwei Li
Xinran Hu
Hao Liang
Juanhua Zhu
Xiaohui Sun
Liuzheng Ma
Min Jiang
Source :
PLoS ONE, Vol 10, Iss 3, p e0122005 (2015)
Publication Year :
2015
Publisher :
Public Library of Science (PLoS), 2015.

Abstract

A surface plasmon resonance (SPR) immunoassay with an immobilization of self-assembled molecular identification membrane for the detection of residual Clenbuterol Hydrochloride (CLB) in pork liver was systematically investigated and experimentally validated for its high performance. SPR immunoassay with a regular competitive inhibition assay cannot be directly verified to detect CLB residuals. In this study, the binding of Au film with mercaptopropionic acid was investigated using the known form of the strong S-Au covalent bonds formed by the chemical radical of the mercaptopropionic acid and the Au film. After that, the immunoglobulin IgG of swine (SwIgG-CLB) was bonded with the mercaptopropionic acid by covalent -CO-NH- amide bonding. The modified comprehensive analysis of how the membrane structure works was introduced together with the customized SPR bioanalyzer. In order to evaluate the performance of this biomembrane structure, the concentrations of CLB-contained solutions of 0 ng · mL(-1), 10 ng · mL(-1), 20 ng · mL(-1), 33.3 ng · mL(-1), and 40 ng · mL(-1) were prepared by adding CLB reagents into the solutions of CLB antibody (Clenbuterol Hydrochloride Antibody, CLB-Ab), successively and then the response unit (RU) was measured individually. Using the data collected from the linear CCD array, the fitting curve was established with the R-Square value of 0.9929. Correspondingly, the recovery rate ranged from 88.48% to 103.21% was experimented and the limit of detection of CLB in 1.26 ng · mL(-1) was obtained efficiently. It was concluded that the detection method associated with biomembrane properties is expected to contribute much to the determination of residual CLB in pork liver quantitatively by using the customized SPR bioanalyzer.

Subjects

Subjects :
Medicine
Science

Details

Language :
English
ISSN :
19326203
Volume :
10
Issue :
3
Database :
Directory of Open Access Journals
Journal :
PLoS ONE
Publication Type :
Academic Journal
Accession number :
edsdoj.2fbb62ffbb4649c992bc7b124175a5bd
Document Type :
article
Full Text :
https://doi.org/10.1371/journal.pone.0122005