Back to Search Start Over

Simulation of Blood Flow Coronary Artery with Consecutive Stenosis and Coronary-Coronary Bypass

Authors :
Omid Arjmandi-Tash
Seyed Esmail Razavi
Ramin Zanbouri
Source :
BioImpacts, Vol 1, Iss 2, Pp 99-104 (2011)
Publication Year :
2011
Publisher :
Tabriz University of Medical Sciences, 2011.

Abstract

Introduction: In this research the behavior of coronary arteries has been studied with symmetric and asymmetric consecutive stenosis, and grafted vessels. Methods: The incompressible Navier-Stokes and energy equations were discretized with second-order upwind method. Assumptions such as Newtonian fluid, wall rigidity and steady-flow were used. Results: All the calculations showed the same results with Newtonians and non-Newtonian fluids. It was found that the possibility of stenosis be reduced by increasing the graft angle. However, there exists further stenosis possibility. Among the three graft angles 20, 30 ̊ and 40, the 30 ̊ was found to be the reliable ones. Conclusion: Based on these findings, it can be deduced that there would be a high risk of further atherosclerosis when the first stenose has the maximum percentage.

Details

Language :
English
ISSN :
22285652 and 22285660
Volume :
1
Issue :
2
Database :
Directory of Open Access Journals
Journal :
BioImpacts
Publication Type :
Academic Journal
Accession number :
edsdoj.3065e7013d424f66b7180c84ea8c7723
Document Type :
article
Full Text :
https://doi.org/10.5681/bi.2011.013