Back to Search Start Over

Direct mitral regurgitation quantification in hypertrophic cardiomyopathy using 4D flow CMR jet tracking: evaluation in comparison to conventional CMR

Authors :
Aakash N. Gupta
Ryan Avery
Gilles Soulat
Bradley D. Allen
Jeremy D. Collins
Lubna Choudhury
Robert O. Bonow
James Carr
Michael Markl
Mohammed S. M. Elbaz
Source :
Journal of Cardiovascular Magnetic Resonance, Vol 23, Iss 1, Pp 1-13 (2021)
Publication Year :
2021
Publisher :
Elsevier, 2021.

Abstract

Abstract Background Quantitative evaluation of mitral regurgitation (MR) in hypertrophic cardiomyopathy (HCM) by cardiovascular magnetic resonance (CMR) relies on an indirect volumetric calculation. The aim of this study was to directly assess and quantify MR jets in patients with HCM using 4D flow CMR jet tracking in comparison to standard-of-care CMR indirect volumetric method. Methods This retrospective study included patients with HCM undergoing 4D flow CMR. By the indirect volumetric method from CMR, MR volume was quantified as left ventricular stroke volume minus forward aortic volume. By 4D flow CMR direct jet tracking, multiplanar reformatted planes were positioned in the peak velocity of the MR jet during systole to calculate through-plane regurgitant flow. MR severity was collected for agreement analysis from a clinical echocardiograms performed within 1 month of CMR. Inter-method and inter-observer agreement were assessed by intraclass correlation coefficient (ICC), Bland–Altman analysis, and Cohen’s kappa. Results Thirty-seven patients with HCM were included. Direct jet tracking demonstrated good inter-method agreement of MR volume compared to the indirect volumetric method (ICC = 0.80, p = 0.004) and fair agreement of MR severity (kappa = 0.27, p = 0.03). Direct jet tracking showed higher agreement with echocardiography (kappa = 0.35, p = 0.04) than indirect volumetric method (kappa = 0.16, p = 0.35). Inter-observer reproducibility of indirect volumetric method components revealed the lowest reproducibility in end-systolic volume (ICC = 0.69, p = 0.15). Indirect volumetric method showed good agreement of MR volume (ICC = 0.80, p = 0.003) and fair agreement of MR severity (kappa = 0.38, p

Details

Language :
English
ISSN :
1532429X
Volume :
23
Issue :
1
Database :
Directory of Open Access Journals
Journal :
Journal of Cardiovascular Magnetic Resonance
Publication Type :
Academic Journal
Accession number :
edsdoj.30c211e2d4c64095a0b8a7c7deea9db7
Document Type :
article
Full Text :
https://doi.org/10.1186/s12968-021-00828-y