Back to Search Start Over

Reversible complete atrioventricular block after percutaneous ASD device closure in a child

Authors :
Manoj Kumar Rohit
Kriti Puri
Ramalingam Vadivelu
Source :
Indian Heart Journal, Vol 66, Iss 3, Pp 366-369 (2014)
Publication Year :
2014
Publisher :
Elsevier, 2014.

Abstract

Transcatheter device closure of atrial septal defect (ASD) in small children less than 15 kg may be associated with increased complications. Complete atrioventricular heart block (CHB) is a rare complication of ASD device closure in such a setting. We report the case of a 2-year-old girl, less than 15 kg, who underwent device closure of ASD with Amplatzer Septal Occluder and subsequently developed CHB 12 h after the procedure which resolved completely with steroid treatment on fifth day. Case report of a similar kind is rarely reported in the literature. Despite adequate postero-inferior margin CHB may still occur in small children as in our case.