Back to Search Start Over

Convolutional mixture of experts model: A comparative study on automatic macular diagnosis in retinal optical coherence tomography imaging

Authors :
Reza Rasti
Alireza Mehridehnavi
Hossein Rabbani
Fedra Hajizadeh
Source :
Journal of Medical Signals and Sensors, Vol 9, Iss 1, Pp 1-14 (2019)
Publication Year :
2019
Publisher :
Wolters Kluwer Medknow Publications, 2019.

Abstract

Background: Macular disorders, such as diabetic macular edema (DME) and age-related macular degeneration (AMD) are among the major ocular diseases. Having one of these diseases can lead to vision impairments or even permanent blindness in a not-so-long time span. So, the early diagnosis of these diseases are the main goals for researchers in the field. Methods: This study is designed in order to present a comparative analysis on the recent convolutional mixture of experts (CMoE) models for distinguishing normal macular OCT from DME and AMD. For this purpose, we considered three recent CMoE models called Mixture ensemble of convolutional neural networks (ME-CNN), Multi-scale Convolutional Mixture of Experts (MCME), and Wavelet-based Convolutional Mixture of Experts (WCME) models. For this research study, the models were evaluated on a database of three different macular OCT sets. Two first OCT sets were acquired by Heidelberg imaging systems consisting of 148 and 45 subjects respectively and set3 was constituted of 384 Bioptigen OCT acquisitions. To provide better performance insight into the CMoE ensembles, we extensively analyzed the models based on the 5-fold cross-validation method and various classification measures such as precision and average area under the ROC curve (AUC). Results: Experimental evaluations showed that the MCME and WCME outperformed the ME-CNN model and presented overall precisions of 98.14% and 96.06% for aligned OCTs respectively. For non-aligned retinal OCTs, these values were 93.95% and 95.56%. Conclusion: Based on the comparative analysis, although the MCME model outperformed the other CMoE models in the analysis of aligned retinal OCTs, the WCME offers a robust model for diagnosis of non-aligned retinal OCTs. This allows having a fast and robust computer-aided system in macular OCT imaging which does not rely on the routine computerized processes such as denoising, segmentation of retinal layers, and also retinal layers alignment.

Details

Language :
English
ISSN :
22287477
Volume :
9
Issue :
1
Database :
Directory of Open Access Journals
Journal :
Journal of Medical Signals and Sensors
Publication Type :
Academic Journal
Accession number :
edsdoj.34c037a6c6eb45e0a10f136d0cb40a06
Document Type :
article
Full Text :
https://doi.org/10.4103/jmss.JMSS_27_17