Back to Search
Start Over
Audit of transvaginal sonography of normal postmenopausal ovaries by sonographers from the United Kingdom Collaborative Trial of Ovarian Cancer Screening (UKCTOCS) [version 1; referees: 2 approved, 1 approved with reservations]
- Source :
- F1000Research, Vol 7 (2018)
- Publication Year :
- 2018
- Publisher :
- F1000 Research Ltd, 2018.
-
Abstract
- Background: We report on a unique audit of seven sonographers self-reporting high visualization rates of normal postmenopausal ovaries in the United Kingdom Collaborative Trial of Ovarian Cancer Screening (UKCTOCS). This audit was ordered by the trial’s Ultrasound Management Subcommittee after an initiative taken in 2008 to improve the quality of scanning and the subsequent increase in the number of sonographers claiming very high ovary visualisation rates. Methods: Seven sonographers reporting high rates (>89%) of visualizing normal postmenopausal ovaries in examinations performed between 1st January and 31st December 2008 were identified. Eight experts in gynaecological scanning reviewed a random selection of exams performed by these sonographers and assessed whether visualization of both ovaries could be confirmed (cVR-Both) in the examinations. A random effects bivariate probit model was fitted to analyse the results. Results: The eight experts reviewed images from 357 examinations performed on 349 postmenopausal women (mean age 60.0 years, range 50.2-73.3) by the seven sonographers. The mean cVR-Both obtained from the model for these sonographers was 67.2% with a range of 47.6-86.5% (95%CI 63.9-70.5%). The range of cVR-Both between the experts was 47.3-88.3% and the intra-class correlation coefficient (ICC) for left and right ovary confirmation was 0.39. Conclusions: The audit suggests that self-reported visualization of postmenopausal ovaries is unreliable, as visualisation of both ovaries could not be confirmed in almost a third of examinations. The agreement for visualization of both ovaries based on review of a static image between experts and sonographers and between expert reviewers alone was only moderate. Further research is needed to develop reliable Quality Control metrics for transvaginal ultrasound.
Details
- Language :
- English
- ISSN :
- 20461402
- Volume :
- 7
- Database :
- Directory of Open Access Journals
- Journal :
- F1000Research
- Publication Type :
- Academic Journal
- Accession number :
- edsdoj.3840e13839474181a7a9bead0daf9247
- Document Type :
- article
- Full Text :
- https://doi.org/10.12688/f1000research.15663.1