Back to Search Start Over

A comparative study of the effect of facet tropism on the index-level kinematics and biomechanics after artificial cervical disc replacement (ACDR) with Prestige LP, Prodisc-C vivo, and Mobi-C: a finite element study

Authors :
Jing Li
Ye Li
Junqi Zhang
Beiyu Wang
Kangkang Huang
Hao Liu
Xin Rong
Source :
Journal of Orthopaedic Surgery and Research, Vol 19, Iss 1, Pp 1-14 (2024)
Publication Year :
2024
Publisher :
BMC, 2024.

Abstract

Abstract Introduction Artificial cervical disc replacement (ACDR) is a widely accepted surgical procedure in the treatment of cervical radiculopathy and myelopathy. However, some research suggests that ACDR may redistribute more load onto the facet joints, potentially leading to postoperative axial pain in certain patients. Earlier studies have indicated that facet tropism is prevalent in the lower cervical spine and can significantly increase facet joint pressure. The present study aims to investigate the changes in the biomechanical environment of the cervical spine after ACDR using different prosthese when facet tropism is present. Methods A C2-C7 cervical spine finite element model was created. Symmetrical, moderate asymmetrical (7 degrees tropism), and severe asymmetrical (14 degrees tropism) models were created at the C5/C6 level by adjusting the left-side facet. C5/C6 ACDR with Prestige LP, Prodisc-C vivo, and Mobi-C were simulated in all models. A 75 N follower load and 1 N⋅m moment was applied to initiate flexion, extension, lateral bending, and axial rotation, and the range of motions (ROMs), facet contact forces(FCFs), and facet capsule stress were recorded. Results In the presence of facet tropism, all ACDR models exhibited significantly higher FCFs and facet capsule stress compared to the intact model. In the asymmetric model, FCFs on the right side were significantly increased in neutral position, extension, left bending and right rotation, and on both sides in right bending and left rotation compared to the symmetric model. All ACDR model in the presence of facet tropism, exhibited significantly higher facet capsule stresses at all positions compared to the symmetric model. The stress distribution on the facet surface and the capsule ligament in the asymmetrical models was different from that in the symmetrical model. Conclusions The existence of facet tropism could considerably increase FCFs and facet capsule stress after ACDR with Prestige-LP, Prodisc-C Vivo, and Mobi-C. None of the three different designs of implants were able to effectively protect the facet joints in the presence of facet tropism. Research into designing new implants may be needed to improve this situation. Clinical trials are needed to validate the impact of facet tropism.

Details

Language :
English
ISSN :
1749799X
Volume :
19
Issue :
1
Database :
Directory of Open Access Journals
Journal :
Journal of Orthopaedic Surgery and Research
Publication Type :
Academic Journal
Accession number :
edsdoj.3a6d6fc141e8475aaa2c0cd76df9f700
Document Type :
article
Full Text :
https://doi.org/10.1186/s13018-024-05218-5