VOC contamination in hospital, from stationary sampling of a large panel of compounds, in view of healthcare workers and patients exposure assessment.

Authors :
Vincent Bessonneau
Luc Mosqueron
Adèle Berrubé
Gaël Mukensturm
Sylvie Buffet-Bataillon
Jean-Pierre Gangneux
Olivier Thomas
Source :
PLoS ONE, Vol 8, Iss 2, p e55535 (2013)
Publication Year :
2013
Publisher :
Public Library of Science (PLoS), 2013.

Abstract

BACKGROUND: We aimed to assess, for the first time, the nature of the indoor air contamination of hospitals. METHODS AND FINDINGS: More than 40 volatile organic compounds (VOCs) including aliphatic, aromatic and halogenated hydrocarbons, aldehydes, alcohols, ketones, ethers and terpenes were measured in a teaching hospital in France, from sampling in six sampling sites--reception hall, patient room, nursing care, post-anesthesia care unit, parasitology-mycology laboratory and flexible endoscope disinfection unit--in the morning and in the afternoon, during three consecutive days. Our results showed that the main compounds found in indoor air were alcohols (arithmetic means ± SD: 928±958 µg/m³ and 47.9±52.2 µg/m³ for ethanol and isopropanol, respectively), ethers (75.6±157 µg/m³ for ether) and ketones (22.6±20.6 µg/m³ for acetone). Concentrations levels of aromatic and halogenated hydrocarbons, ketones, aldehydes and limonene were widely variable between sampling sites, due to building age and type of products used according to health activities conducted in each site. A high temporal variability was observed in concentrations of alcohols, probably due to the intensive use of alcohol-based hand rubs in all sites. Qualitative analysis of air samples led to the identification of other compounds, including siloxanes (hexamethyldisiloxane, octamethyltrisiloxane, decamethylcyclopentasiloxane), anesthetic gases (sevoflurane, desflurane), aliphatic hydrocarbons (butane), esters (ethylacetate), terpenes (camphor, α-bisabolol), aldehydes (benzaldehyde) and organic acids (benzoic acid) depending on sites. CONCLUSION: For all compounds, concentrations measured were lower than concentrations known to be harmful in humans. However, results showed that indoor air of sampling locations contains a complex mixture of VOCs. Further multicenter studies are required to compare these results. A full understanding of the exposure of healthcare workers and patients to complex mixtures of chemical compounds can then be related to potential health outcomes.

Subjects

Subjects :
Medicine
Science

Details

Language :
English
ISSN :
19326203
Volume :
8
Issue :
2
Database :
Directory of Open Access Journals
Journal :
PLoS ONE
Publication Type :
Academic Journal
Accession number :
edsdoj.3ebd22a9baa844f793cb62b0d64cf882
Document Type :
article
Full Text :
https://doi.org/10.1371/journal.pone.0055535