Comparison among TonoVet, TonoVet Plus, Tono-Pen Avia Vet, and Kowa HA-2 portable tonometers for measuring intraocular pressure in dogs

Authors :
João Victor Goulart Consoni Passareli
Felipe Franco Nascimento
Giovana José Garcia Estanho
Claudia Lizandra Ricci
Glaucia Prada Kanashiro
Rogério Giuffrida
Silvia Franco Andrade
Source :
Veterinary World, Vol 14, Iss 9, Pp 2444-2451 (2021)
Publication Year :
2021
Publisher :
Veterinary World, 2021.

Abstract

Background and Aim: Tonometers are an important instrument for measuring intraocular pressure (IOP) in the diagnosis of glaucoma or uveitis. This study aimed to compare the accuracy of the main types of tonometers with different IOP measurement methodologies in dogs: TonoVet and TonoVet Plus (rebound), Tono-Pen Avia Vet (applanation), and Kowa HA-2 (Goldmann applanation). Materials and Methods: IOP was measured in 152 eyes of 76 dogs. A postmortem study was performed by comparing manometry and tonometry values and calculating the correlation coefficient (r2), in vivo real IOP (manometry) among the tonometers was compared, and an outpatient study was conducted with healthy eyes and eyes with signs of glaucoma and uveitis. Results: In the postmortem study, the values of r2 in descending order were Kowa (0.989), TonoVet Plus (0.984), TonoVet (0.981), and Tono-Pen Avia Vet (0.847). The IOP values in mmHg in the in vivo study were as follows: Aneroid manometer (16.8±2.5.7), TonoVet (18.1±2.9), TonoVet Plus (20.6±2.3), Tono-Pen Avia Vet (17.1±2.5), and Kowa (16.1±1.7); in outpatient clinics: TonoVet (16.8±3.8), TonoVet Plus (19.2±2.9), Tono-Pen Avia Vet (16.2±2.4), and Kowa (15.0±1.3); glaucoma: TonoVet (30.2±3.5), TonoVet Plus (35.0±6.1), Tono-Pen Avia Vet (29.5±4.2), and Kowa (23.9±5.0); and uveitis: TonoVet (14.2±1.4), TonoVet Plus (17.6±1.9), Tono-Pen Avia Vet (13.7±2.1), and Kowa (12.6±1.7). Conclusion: There was a strong correlation between IOP values and manometry in all the tonometers. The highest values were obtained with TonoVet Plus and the lowest with Kowa HA-2. All tonometers accurately measured IOP in dogs, including the latest TonoVet Plus, which showed an excellent correlation coefficient.

Details

Language :
English
ISSN :
09728988 and 22310916
Volume :
14
Issue :
9
Database :
Directory of Open Access Journals
Journal :
Veterinary World
Publication Type :
Academic Journal
Accession number :
edsdoj.4083fa0162444557a6755303ab455b56
Document Type :
article
Full Text :
https://doi.org/10.14202/vetworld.2021.2444-2451