Pressure drop during evaporation of 1,1,1,2-tetrafluoroethane (R-134a)in a plate heat exchanger
- Source :
- Journal of the Serbian Chemical Society, Vol 72, Iss 10, Pp 1015-1022 (2007)
- Publication Year :
- 2007
- Publisher :
- Serbian Chemical Society, 2007.
-
Abstract
- Experimental results for the pressure drop during the evaporation of the refrigerant 1,1,1,2-tetrafluoroethane (R-134a) in a vertical plate heat exchanger are presented in this paper. The influences of mass flux, heat flux and vapor quality on the two-phase pressure drop are specially analyzed and compared with previously published experimental data and literature correlations. All results are given in graphical form as the dependency of the frictional pressure drop on the mean vapor quality. .
Details
- Language :
- English
- ISSN :
- 03525139 and 18207421
- Volume :
- 72
- Issue :
- 10
- Database :
- Directory of Open Access Journals
- Journal :
- Journal of the Serbian Chemical Society
- Publication Type :
- Academic Journal
- Accession number :
- edsdoj.41c35a46cae040828f10c5285e064a3a
- Document Type :
- article
- Full Text :
- https://doi.org/10.2298/JSC0710015D