Back to Search Start Over

GLM-based optimization of NGS data analysis: A case study of Roche 454, Ion Torrent PGM and Illumina NextSeq sequencing data.

Authors :
Sarah Sandmann
Aniek O de Graaf
Bert A van der Reijden
Joop H Jansen
Martin Dugas
Source :
PLoS ONE, Vol 12, Iss 2, p e0171983 (2017)
Publication Year :
2017
Publisher :
Public Library of Science (PLoS), 2017.

Abstract

BACKGROUND:There are various next-generation sequencing techniques, all of them striving to replace Sanger sequencing as the gold standard. However, false positive calls of single nucleotide variants and especially indels are a widely known problem of basically all sequencing platforms. METHODS:We considered three common next-generation sequencers-Roche 454, Ion Torrent PGM and Illumina NextSeq-and applied standard as well as optimized variant calling pipelines. Optimization was achieved by combining information of 23 diverse parameters characterizing the reported variants and generating individually calibrated generalized linear models. Models were calibrated using amplicon-based targeted sequencing data (19 genes, 28,775 bp) from seven to 12 myelodysplastic syndrome patients. Evaluation of the optimized pipelines and platforms was performed using sequencing data from three additional myelodysplastic syndrome patients. RESULTS:Using standard analysis methods, true mutations were missed and the obtained results contained many artifacts-no matter which platform was considered. Analysis of the parameters characterizing the true and false positive calls revealed significant platform- and variant specific differences. Application of optimized variant calling pipelines considerably improved results. 76% of all false positive single nucleotide variants and 97% of all false positive indels could be filtered out. Positive predictive values could be increased by factors of 1.07 to 1.27 in case of single nucleotide variant calling and by factors of 3.33 to 53.87 in case of indel calling. Application of the optimized variant calling pipelines leads to comparable results for all next-generation sequencing platforms analyzed. However, regarding clinical diagnostics it needs to be considered that even the optimized results still contained false positive as well as false negative calls.

Subjects

Subjects :
Medicine
Science

Details

Language :
English
ISSN :
19326203
Volume :
12
Issue :
2
Database :
Directory of Open Access Journals
Journal :
PLoS ONE
Publication Type :
Academic Journal
Accession number :
edsdoj.43ea4e6f9aa54eeaacea0ca16668f81c
Document Type :
article
Full Text :
https://doi.org/10.1371/journal.pone.0171983