Back to Search Start Over

A randomized control trial to assess optical coherence tomography parameters of the Xlimus drug-eluting stent: the XLIMIT trial

Authors :
Luca Testa
Mattia Squillace
Nicoletta Ventrella
Raul Moreno
Santiago Jiménez-Valero
Antoni Serra
Joan Antoni Gomez Hospital
Michele Bellamoli
Antonio Popolo Rubbio
Francesco Bedogni
Source :
Frontiers in Cardiovascular Medicine, Vol 10 (2023)
Publication Year :
2023
Publisher :
Frontiers Media S.A., 2023.

Abstract

BackgroundThird generation drug-eluting stents (DES) potentially offer better technical performance and reduced neointimal proliferation than previous generation DES. The XLIMIT non-inferiority trial evaluated the performance of the Xlimus (a novel sirolimus-eluting coronary stent system) in terms of endothelialization and tissue healing compared to the bioresorbable polymer Synergy DES.MethodsA total of 177 patients undergoing percutaneous coronary intervention (PCI) were randomized in a 2:1 ratio (2 Xlimus: 1 Synergy). The primary endpoints, defined as the in-stent neointimal volume weighted by the sum of the lengths of the implanted stent (ISNV) and the in-stent neointimal percent volume obstruction (%VO) were evaluated at 6–9 months by means of optical coherence tomography (OCT). Additional OCT parameters as well as clinical endpoints were also collected.ResultsMost of the patients were males (77.4%), and the mean age was 64 years. One third of the population had stable angina/silent ischemia. A total of 300 stents (237 lesions) were analyzed: 198 (152 lesions) were in the Xlimus group, and 102 (85 lesions) in the Synergy group. The ISNV in the Xlimus group was 30.7 ± 24.5 mm3 while in the Synergy group it was 26.5 ± 26.7 mm3: the difference between the two means was 0.08 (−0, 04–0, 45), p = 0.018, thus meeting the non-inferiority hypothesis. The %VO was 16.3% ± 10.4% and 13.3% ± 10.8% in the Xlimus and Synergy groups, respectively: the difference between the two means was 3.0 (−0, 06–4, 2), (p = 0.01), thus meeting the non-inferiority hypothesis. No difference was found with respect to the secondary OCT endpoints as well as for clinical endpoints.ConclusionsThe study results confirm that the biological interaction of the Xlimus and Synergy DES with the coronary artery is comparable, and that translates in very reassuring OCT parameters at follow-up: as such, the Xlimus is non-inferior to the Synergy.Clinical Trial RegistrationClinicalTrials.gov, identifier (NCT03745053).

Details

Language :
English
ISSN :
2297055X
Volume :
10
Database :
Directory of Open Access Journals
Journal :
Frontiers in Cardiovascular Medicine
Publication Type :
Academic Journal
Accession number :
edsdoj.4532ebd3fb14cd69c15d4b57693d99c
Document Type :
article
Full Text :
https://doi.org/10.3389/fcvm.2023.1199475