Back to Search Start Over

Comparison of Two-dimensional and Three-dimensional Features of Chest CT in the Diagnosis of Invasion of Pulmonary Ground Glass Nodules

Authors :
Hongya WANG
He YANG
Zicheng LIU
Liang CHEN
Xinfeng XU
Quan ZHU
Source :
Chinese Journal of Lung Cancer, Vol 25, Iss 10, Pp 723-729 (2022)
Publication Year :
2022
Publisher :
Chinese Anti-Cancer Association; Chinese Antituberculosis Association, 2022.

Abstract

Background and objective At present, more and more studies predict invasive adenocarcinoma (IAC) through three-dimensional features of pulmonary nodules, but few studies have confirmed that three-dimensional features have more advantages in diagnosing IAC than traditional two-dimensional features of pulmonary nodules. This study analyzed the differences of chest computed tomography (CT) features between IAC and minimally invasive adenocarcinoma (MIA) from three-dimensional and two-dimensional levels, and compared the ability of diagnosing IAC. The non-invasive adenocarcinoma group includes precursor glandular lesions (PGL) and minimally invasive adenocarcinoma (MIA). Methods The clinical data of 1,045 patients with ground glass opacity (GGO) from January to December 2019 were collected. Then the correlation between preoperative CT image characteristics and pathological results were analyzed retrospectively. The independent influencing factors for the identification of IAC were screened out according to two-dimensional and three-dimensional classification by multivariate Logistic regression and the cut-off point for the identification of IAC was found out through the receiver operating characteristic (ROC) curve. At last, the ability of diagnosing IAC was evaluated by Yoden index. Results The diameter of nodule, the diameter of solid component, the diameter of mediastinal window nodule in two-dimensional factors, and the volume of nodule, the volume of solid part and the average CT value in three-dimensional factors were independent risk factors for the diagnosis of IAC. These factors were arranged by Yoden index: solid partial volume (0.601)>nodule volume (0.536)>solid component diameter (0.525)>nodule diameter (0.518)>mediastinal window nodule diameter (0.488)>proportion of solid component volume (0.471)>1-tumor disappearance ratio (TDR) (0.468)>consolidation tumor ratio (CTR) (0.394)>average CT value (0.380). Conclusion The CT features of three-dimensional are better than two-dimensional in the diagnosis of IAC, and the size of solid components is better than the overall size of nodules.

Details

Language :
Chinese
ISSN :
10093419 and 19996187
Volume :
25
Issue :
10
Database :
Directory of Open Access Journals
Journal :
Chinese Journal of Lung Cancer
Publication Type :
Academic Journal
Accession number :
edsdoj.45479ea14bb541f09500827daddbdd21
Document Type :
article
Full Text :
https://doi.org/10.3779/j.issn.1009-3419.2022.102.39