Back to Search
Start Over
Refractory ineffective triggering during pressure support ventilation: effect of proportional assist ventilation with load-adjustable gain factors
- Source :
- Annals of Intensive Care, Vol 11, Iss 1, Pp 1-11 (2021)
- Publication Year :
- 2021
- Publisher :
- SpringerOpen, 2021.
-
Abstract
- Abstract Background Ineffective triggering is frequent during pressure support ventilation (PSV) and may persist despite ventilator adjustment, leading to refractory asynchrony. We aimed to assess the effect of proportional assist ventilation with load-adjustable gain factors (PAV+) on the occurrence of refractory ineffective triggering. Design Observational assessment followed by prospective cross-over physiological study. Setting Academic medical ICU. Patients Ineffective triggering was detected during PSV by a twice-daily inspection of the ventilator’s screen. The impact of pressure support level (PSL) adjustments on the occurrence of asynchrony was recorded. Patients experiencing refractory ineffective triggering, defined as persisting asynchrony at the lowest tolerated PSL, were included in the physiological study. Interventions Physiological study: Flow, airway, and esophageal pressures were continuously recorded during 10 min under PSV with the lowest tolerated PSL, and then under PAV+ with the gain adjusted to target a muscle pressure between 5 and 10 cmH2O. Measurements Primary endpoint was the comparison of asynchrony index between PSV and PAV+ after PSL and gain adjustments. Results Among 36 patients identified having ineffective triggering under PSV, 21 (58%) exhibited refractory ineffective triggering. The lowest tolerated PSL was higher in patients with refractory asynchrony as compared to patients with non-refractory ineffective triggering. Twelve out of the 21 patients with refractory ineffective triggering were included in the physiological study. The median lowest tolerated PSL was 17 cmH2O [12–18] with a PEEP of 7 cmH2O [5–8] and FiO2 of 40% [39–42]. The median gain during PAV+ was 73% [65–80]. The asynchrony index was significantly lower during PAV+ than PSV (2.7% [1.0–5.4] vs. 22.7% [10.3–40.1], p
Details
- Language :
- English
- ISSN :
- 21105820
- Volume :
- 11
- Issue :
- 1
- Database :
- Directory of Open Access Journals
- Journal :
- Annals of Intensive Care
- Publication Type :
- Academic Journal
- Accession number :
- edsdoj.4b848b0d782742169951d71303a0af4d
- Document Type :
- article
- Full Text :
- https://doi.org/10.1186/s13613-021-00935-0