Back to Search
Start Over
Total marrow lymphoid irradiation IMRT treatment using a novel CT-linac
- Source :
- European Journal of Medical Research, Vol 28, Iss 1, Pp 1-10 (2023)
- Publication Year :
- 2023
- Publisher :
- BMC, 2023.
-
Abstract
- Abstract Background A novel CT-linac (kilovolt fan-beam CT-linac) has been introduced into total marrow and lymphoid irradiation (TMLI) treatment. Its integrated kilovolt fan-beam CT (kV FBCT) can be used not only for image guidance (IGRT) but also to re-calculate the dose. Purpose This study reported our clinical routine on performing TMIL treatment on the CT-linac, as well as dose distribution comparison between planned and re-calculated based on IGRT FBCT image sets. Methods 11 sets of data from 5 male and 6 female patients who had underwent the TMLI treatment with uRT-linac 506c were selected for this study. The planning target volumes consist of all skeletal bones exclusion of the mandible and lymphatic sanctuary sites. A planned dose of 10 Gy was prescribed to all skeletal bones exclusion of the mandible in two fractions and 12 Gy in two fractions was prescribed to lymphatic sanctuary sites. Each TMLI plan contained two sub-plans, one dynamic IMRT for the upper body and the other VMAT for the lower extremity. Two attempts were made to obtain homogeneous dose in the overlapping region, i.e., applying two plans with different isocenters for the treatment of two fractions, and using a dose gradient matching scheme. The CT scans, including planning CT and IGRT FBCT, were stitched to a whole body CT scan for dose distribution evaluation. Results The average beam-on time of Planupper is 30.6 min, ranging from 24.9 to 37.5 min, and the average beam-on time of Planlower is 6.3 min, ranging from 5.7 to 8.2 min. For the planned dose distribution, the 94.79% of the PTVbone is covered by the prescription dose of 10 Gy (V10), and the 94.68% of the PTVlymph is covered by the prescription dose of 12 Gy (V12). For the re-calculated dose distribution, the 92.17% of the PTVbone is covered by the prescription dose of 10 Gy (V10), and the 90.07% of the PTVlymph is covered by the prescription dose of 12 Gy (V12). The results showed that there is a significant difference (p 0.05) between planned dose and re-calculated dose on selected organs, except for right lens (p
Details
- Language :
- English
- ISSN :
- 2047783X
- Volume :
- 28
- Issue :
- 1
- Database :
- Directory of Open Access Journals
- Journal :
- European Journal of Medical Research
- Publication Type :
- Academic Journal
- Accession number :
- edsdoj.525c4b37f11c4e429561d6a6809a3a84
- Document Type :
- article
- Full Text :
- https://doi.org/10.1186/s40001-023-01380-4