Back to Search Start Over

Studying temporal titre evolution of commercial SARS-CoV-2 assays reveals significant shortcomings of using BAU standardization for comparison

Authors :
Inge Kroidl
Simon Winter
Raquel Rubio-Acero
Abhishek Bakuli
Christof Geldmacher
Tabea M. Eser
Flora Déak
Sacha Horn
Anna Zielke
Mohamed I. M. Ahmed
Paulina Diepers
Jessica Guggenbühl
Jonathan Frese
Jan Bruger
Kerstin Puchinger
Jakob Reich
Philine Falk
Alisa Markgraf
Heike Fensterseifer
Ivana Paunovic
Angelika Thomschke
Michael Pritsch
Friedrich Riess
Elmar Saathoff
Michael Hoelscher
Laura Olbrich
Noemi Castelletti
Andreas Wieser
KoCo19/ORCHESTRA Study Group
Source :
Virology Journal, Vol 20, Iss 1, Pp 1-12 (2023)
Publication Year :
2023
Publisher :
BMC, 2023.

Abstract

Abstract Background Measuring specific anti-SARS-CoV-2 antibodies has become one of the main epidemiological tools to survey the ongoing SARS-CoV-2 pandemic, but also vaccination response. The WHO made available a set of well-characterized samples derived from recovered individuals to allow normalization between different quantitative anti-Spike assays to defined Binding Antibody Units (BAU). Methods To assess sero-responses longitudinally, a cohort of ninety-nine SARS-CoV-2 RT-PCR positive subjects was followed up together with forty-five vaccinees without previous infection but with two vaccinations. Sero-responses were evaluated using a total of six different assays: four measuring anti-Spike proteins (converted to BAU), one measuring anti-Nucleocapsid proteins and one SARS-CoV-2 surrogate virus neutralization. Both cohorts were evaluated using the Euroimmun Anti-SARS-CoV-2-ELISA anti-S1 IgG and the Roche Elecsys Anti-SARS-CoV-2 anti-S1 assay. Results In SARS-CoV-2-convalesce subjects, the BAU-sero-responses of Euroimmun Anti-SARS-CoV-2-ELISA anti-S1 IgG and Roche Elecsys Anti-SARS-CoV-2 anti-S1 peaked both at 47 (43–51) days, the first assay followed by a slow decay thereafter (> 208 days), while the second assay not presenting any decay within one year. Both assay values in BAUs are only equivalent a few months after infection, elsewhere correction factors up to 10 are necessary. In contrast, in infection-naive vaccinees the assays perform similarly. Conclusion The results of our study suggest that the establishment of a protective correlate or vaccination booster recommendation based on different assays, although BAU-standardised, is still challenging. At the moment the characteristics of the available assays used are not related, and the BAU-standardisation is unable to correct for that.

Details

Language :
English
ISSN :
1743422X
Volume :
20
Issue :
1
Database :
Directory of Open Access Journals
Journal :
Virology Journal
Publication Type :
Academic Journal
Accession number :
edsdoj.52da37c38f49f8bce7f21e0eef5e1b
Document Type :
article
Full Text :
https://doi.org/10.1186/s12985-023-02167-z