Back to Search Start Over

Long-Term Mortality After TAVI for Bicuspid vs. Tricuspid Aortic Stenosis: A Propensity-Matched Multicentre Cohort Study

Authors :
Aleksandra Gasecka
Michał Walczewski
Adam Witkowski
Maciej Dabrowski
Zenon Huczek
Radosław Wilimski
Andrzej Ochała
Radosław Parma
Piotr Scisło
Bartosz Rymuza
Karol Zbroński
Piotr Szwed
Marek Grygier
Anna Olasińska-Wiśniewska
Dariusz Jagielak
Radosław Targoński
Grzegorz Opolski
Janusz Kochman
Source :
Frontiers in Cardiovascular Medicine, Vol 9 (2022)
Publication Year :
2022
Publisher :
Frontiers Media S.A., 2022.

Abstract

ObjectivesPatients with bicuspid aortic valve (BAV) stenosis were excluded from the pivotal trials of transcatheter aortic valve implantation (TAVI). We compared the in-hospital and long-term outcomes between patients undergoing TAVI for bicuspid and tricuspid aortic valve (TAV) stenosis.MethodsWe performed a retrospective registry-based analysis on patients who underwent TAVI for BAV and TAV at five different centers between January 2009 and August 2017. The primary outcome was long-term all-cause mortality. Secondary outcomes were in-hospital mortality, procedural complications, and valve performance.ResultsOf 1,451 consecutive patients who underwent TAVI, two propensity-matched cohorts consisting of 130 patients with BAV and 390 patients with TAV were analyzed. All-cause mortality was comparable in both groups up to 10 years following TAVI (HR 1.09, 95% CI: 0.77–1.51). Device success and in-hospital mortality were comparable between the groups (96 vs. 95%, p = 0.554 and 2.3 vs. 2.1%, p = 0.863, respectively). Incidence of procedural complications was similar in both groups, with a trend toward a higher rate of stroke in patients with BAV (5 vs. 2%, p = 0.078). Incidence of moderate or severe paravalvular leak (PVL) at discharge was comparable in both groups (2 vs. 2%, p = 0.846). Among patients with BAV, all-cause mortality was similar in self-expanding and balloon-expandable prostheses (HR 1.02, 95% CI: 0.52–1.99) and lower in new-generation devices compared to old-generation valves (HR 0.27, 95% CI 0.12–0.62).ConclusionPatients who had undergone TAVI for BAV had comparable mortality to patients with TAV up to 10 years after the procedure. The device success, in-hospital mortality, procedural complications, and PVL rate were comparable between the groups. The high rate of neurological complications (5%) in patients with BAV warrants further investigation.

Details

Language :
English
ISSN :
2297055X
Volume :
9
Database :
Directory of Open Access Journals
Journal :
Frontiers in Cardiovascular Medicine
Publication Type :
Academic Journal
Accession number :
edsdoj.53a2998c1b342658070a80f0fdad6f7
Document Type :
article
Full Text :
https://doi.org/10.3389/fcvm.2022.894497