Back to Search Start Over

Validity and reliability of smartphone applications for measurement of hip rotation, compared with three‐dimensional motion analysis

Authors :
Phob Ganokroj
Nuchanun Sompornpanich
Pichitpol Kerdsomnuek
Bavornrat Vanadurongwan
Pisit Lertwanich
Source :
BMC Musculoskeletal Disorders, Vol 22, Iss 1, Pp 1-9 (2021)
Publication Year :
2021
Publisher :
BMC, 2021.

Abstract

Abstract Background Measurement of hip rotation is a crucial clinical parameter for the identification of hip problems and the monitoring of symptoms. The objective of this study was to determine whether the use of two smartphone applications is valid and reliable for the measurement of hip rotation. Methods An experimental, cross-sectional study was undertaken to assess passive hip internal and external rotation in three positions by two examiners. The hip rotational angles were measured by a smartphone clinometer application in the sitting and prone positions, and by a smartphone compass application in the supine position; their results were compared with those of the standard, three-dimensional, motion analysis system. The validities and inter-rater and intra-rater reliabilities of the smartphone applications were evaluated. Results The study involved 24 participants. The validities were good to excellent for the internal rotation angles in all positions (ICC 0.81–0.94), good for the external rotation angles in the prone position (ICC 0.79), and fair for the sitting and supine positions (ICC 0.70–0.73). The measurement of the hip internal rotation in the supine position had the highest ICC value of 0.94 (0.91, 0.96). The two smartphone applications showed good-to-excellent intra-rater reliability, but good-to-excellent inter-rater reliability for only three of the six positions (two other positions had fair reliability, while one position demonstrated poor reliability). Conclusions The two smartphone applications have good-to-excellent validity and intra-rater reliability, but only fair-to-good inter-rater reliability for the measurement of the hip rotational angle. The most valid hip rotational position in this study was the supine IR angle measurement, while the lowest validity was the ER angle measurement in the sitting position. The smartphone application is one of the practical measurements in hip rotational angles. Trial registration Number 20181022003 at the Thai Clinical Trials Registry ( http://www.clinicaltrials.in.th ) which was retrospectively registered at 2018-10-18 15:30:29.

Details

Language :
English
ISSN :
14712474
Volume :
22
Issue :
1
Database :
Directory of Open Access Journals
Journal :
BMC Musculoskeletal Disorders
Publication Type :
Academic Journal
Accession number :
edsdoj.5bf54a3941400f93f82d0e940c9ab0
Document Type :
article
Full Text :
https://doi.org/10.1186/s12891-021-03995-2