Back to Search Start Over

Microplastic analysis in soils: A comparative assessment

Authors :
Stoyana Peneva
Quynh Nhu Phan Le
Davi R. Munhoz
Olivia Wrigley
Flora Wille
Heidi Doose
Crispin Halsall
Paula Harkes
Michael Sander
Melanie Braun
Wulf Amelung
Source :
Ecotoxicology and Environmental Safety, Vol 289, Iss , Pp 117428- (2025)
Publication Year :
2025
Publisher :
Elsevier, 2025.

Abstract

Microplastic (MiP) contamination poses environmental risks, but harmonizing data from different quantification methods and sample matrices remains challenging. We compared analytical protocols for MiP quantification in soil, consisting of Digital, Fluorescence, Fourier-transform infrared (FTIR), and Raman Microscopy as well as quantitative Pyrolysis-Gas Chromatography-Mass Spectroscopy (Py-GC-MS) and 1-proton nuclear magnetic resonance (1H NMR) spectroscopy as detection techniques. Each technique was coupled with a specific extraction procedure and evaluated for three soils with different textures and organic carbon contents, amended with eight types of large MiPs (0.5–1 mm) – high- and low-density polyethylene (HDPE and LDPE), polypropylene (PP), polystyrene (PS), polyamide (PA), polyethylene terephthalate (PET), polyvinyl chloride (PVC), and a biodegradable mulch film product composed of polybutylene adipate-co-terephthalate/ polylactic acid (PBAT/ PLA). In addition, we included two types of small MiPs (20–250 µm) composed of either LDPE or PBAT/ PLA in the tests. The results showed that protocols for Digital, Fluorescence, and ATR-FTIR microscopy recovered 74–98 % of the large MiPs, with fluorescence yielding the highest recoveries. Raman spectroscopy was most sensitive to soil organic matter residues, requiring more sophisticated sample pretreatment. Fluorescence staining with subsequent Fluorescence microscopy detection effectively recovered most small-sized LDPE-MiP but missed 56–93 % of small PBAT/ PLA particles. For the latter, reliable quantification was achieved only using Soxhlet extraction combined with 1H NMR spectroscopic quantification. Pyrolysis-GC-MS showed intermediate results, displaying low sensitivity to plastic type and lower recoveries as soil clay content increased. We conclude that different methods have different sensitivities for different MiP materials in different soils, i.e. comparisons of MiP loads and threshold settings for MiP loads across methodologies require careful consideration. Yet, our data indicate that adding stained large MiP as an internal standard could enhance extraction control, while Soxhlet-extraction with subsequent 1H NMR analysis is most powerful for controlling future thresholds of small MiP from biodegradable materials.

Details

Language :
English
ISSN :
01476513
Volume :
289
Issue :
117428-
Database :
Directory of Open Access Journals
Journal :
Ecotoxicology and Environmental Safety
Publication Type :
Academic Journal
Accession number :
edsdoj.6019052835b2449a9f1de01a7c160d23
Document Type :
article
Full Text :
https://doi.org/10.1016/j.ecoenv.2024.117428