Back to Search Start Over

Finding the limits of deep learning clinical sensitivity with fractional anisotropy (FA) microstructure maps

Authors :
Marta Gaviraghi
Antonio Ricciardi
Fulvia Palesi
Wallace Brownlee
Paolo Vitali
Ferran Prados
Baris Kanber
Claudia A. M. Gandini Wheeler-Kingshott
Source :
Frontiers in Neuroinformatics, Vol 18 (2024)
Publication Year :
2024
Publisher :
Frontiers Media S.A., 2024.

Abstract

BackgroundQuantitative maps obtained with diffusion weighted (DW) imaging, such as fractional anisotropy (FA) –calculated by fitting the diffusion tensor (DT) model to the data,—are very useful to study neurological diseases. To fit this map accurately, acquisition times of the order of several minutes are needed because many noncollinear DW volumes must be acquired to reduce directional biases. Deep learning (DL) can be used to reduce acquisition times by reducing the number of DW volumes. We already developed a DL network named “one-minute FA,” which uses 10 DW volumes to obtain FA maps, maintaining the same characteristics and clinical sensitivity of the FA maps calculated with the standard method using more volumes. Recent publications have indicated that it is possible to train DL networks and obtain FA maps even with 4 DW input volumes, far less than the minimum number of directions for the mathematical estimation of the DT.MethodsHere we investigated the impact of reducing the number of DW input volumes to 4 or 7, and evaluated the performance and clinical sensitivity of the corresponding DL networks trained to calculate FA, while comparing results also with those using our one-minute FA. Each network training was performed on the human connectome project open-access dataset that has a high resolution and many DW volumes, used to fit a ground truth FA. To evaluate the generalizability of each network, they were tested on two external clinical datasets, not seen during training, and acquired on different scanners with different protocols, as previously done.ResultsUsing 4 or 7 DW volumes, it was possible to train DL networks to obtain FA maps with the same range of values as ground truth - map, only when using HCP test data; pathological sensitivity was lost when tested using the external clinical datasets: indeed in both cases, no consistent differences were found between patient groups. On the contrary, our “one-minute FA” did not suffer from the same problem.ConclusionWhen developing DL networks for reduced acquisition times, the ability to generalize and to generate quantitative biomarkers that provide clinical sensitivity must be addressed.

Details

Language :
English
ISSN :
16625196
Volume :
18
Database :
Directory of Open Access Journals
Journal :
Frontiers in Neuroinformatics
Publication Type :
Academic Journal
Accession number :
edsdoj.6401885f4894a57bfc38088e43c5a11
Document Type :
article
Full Text :
https://doi.org/10.3389/fninf.2024.1415085