Back to Search
Start Over
Transient Electromagnetic Response With a Ramp Current Excitation Using Conical Source
- Source :
- IEEE Access, Vol 7, Pp 63829-63836 (2019)
- Publication Year :
- 2019
- Publisher :
- IEEE, 2019.
-
Abstract
- In this paper, transient electromagnetic response excited by ramp-shaped current using a conical source is studied for the sensing of underground environments. The transient time responses from the conical source with either multi-turn coils or a single loop coil are investigated and compared. Although with the same magnetic moment, the turn-off time for conical source is longer than that of the single loop-this is due to the fact that the time of entering different testing stages using a multi-turn coil system is often earlier than that for a single loop system. To correct turn-off error, the conical source type transmitter is used and the one-dimensional modeling of a layered media, in which the calculation of the turn-off response is carried over the entire time range by solving directly an upper limit-variable integral. The turn-off correction method matched the resistivity and the layer thickness, which is critical for the detection of shallow depth problems. Finally, a field example is presented to illustrate the effect of turn-off time on the interpretation of transient sounding data for a conical source system.
Details
- Language :
- English
- ISSN :
- 21693536
- Volume :
- 7
- Database :
- Directory of Open Access Journals
- Journal :
- IEEE Access
- Publication Type :
- Academic Journal
- Accession number :
- edsdoj.6638a49781c442baa47c1f0a6f4455b9
- Document Type :
- article
- Full Text :
- https://doi.org/10.1109/ACCESS.2019.2914740