Detection of Pipes Causing Pressure Loss in Water Distribution Networks via Artificial Immune Systems

Authors :
Mirac Eryiğit
Source :
Düzce Üniversitesi Bilim ve Teknoloji Dergisi, Vol 11, Iss 4, Pp 2236-2245 (2023)
Publication Year :
2023
Publisher :
Düzce University, 2023.

Abstract

This paper proposes the optimization model using Artificial Immune Systems, depending on a model calibration, in order to determine worn out pipes with low Hazen-Williams roughness coefficient causing pressure loss in the water distribution networks. The modified Clonal Selection Algorithm, a type of Artificial Immune Systems, was used as a heuristic optimization method. In order to evaluate its performance, the model was implemented to the four-loop hypothetical water distribution network under steady-state conditions. According to the results, the model appeared to be promising in the detection of old pipes causing high pressure losses in the water distribution networks

Details

Language :
English, Turkish
ISSN :
21482446
Volume :
11
Issue :
4
Database :
Directory of Open Access Journals
Journal :
Düzce Üniversitesi Bilim ve Teknoloji Dergisi
Publication Type :
Academic Journal
Accession number :
edsdoj.68f544378eda4784a5d40dcc6c840b77
Document Type :
article
Full Text :
https://doi.org/10.29130/dubited.1158728