Back to Search Start Over

Evaluation of Global Decametric-Resolution LAI, FAPAR and FVC Estimates Derived from Sentinel-2 Imagery

Authors :
Qiong Hu
Jingya Yang
Baodong Xu
Jianxi Huang
Muhammad Sohail Memon
Gaofei Yin
Yelu Zeng
Jing Zhao
Ke Liu
Source :
Remote Sensing, Vol 12, Iss 6, p 912 (2020)
Publication Year :
2020
Publisher :
MDPI AG, 2020.

Abstract

Global biophysical products at decametric resolution derived from Sentinel-2 imagery have emerged as a promising dataset for fine-scale ecosystem modeling and agricultural monitoring. Evaluating uncertainties of different Sentinel-2 biophysical products over various regions and vegetation types is pivotal in the application of land surface models. In this study, we quantified the performance of Sentinel-2-derived Leaf Area Index (LAI), Fraction of Absorbed Photosynthetically Active Radiation (FAPAR), and Fractional Vegetation Cover (FVC) estimates using global ground observations with consistent measurement criteria. Our results show that the accuracy of vegetation and non-vegetated classification based on Sentinel-2 surface reflectance products is greater than 95%, which indicates the vegetation identification is favorable for the practical application of biophysical estimates, as several LAI, FAPAR, and FVC retrievals were derived for non-vegetated pixels. The rate of best retrievals is similar between LAI and FAPAR estimates, both accounting for 87% of all vegetation pixels, while it is almost 100% for FVC estimates. Additionally, the Sentinel-2 FAPAR and FVC estimates agree well with ground-measurements-derived (GMD) reference maps, whereas a large discrepancy is observed for Sentinel-2 LAI estimates by comparing with both GMD effective LAI (LAIe) and actual LAI (LAI) reference maps. Furthermore, the uncertainties of Sentinel-2 LAI, FAPAR and FVC estimates are 1.09 m2/m2, 1.14 m2/m2, 0.13 and 0.17 through comparisons to ground LAIe, LAI, FAPAR, and FVC measurements, respectively. Given the temporal difference between Sentinel-2 observations and ground measurements, Sentinel-2 LAI estimates are more consistent with LAIe than LAI values. The robustness of evaluation results can be further improved as long as more multi-temporal ground measurements across different regions are obtained. Overall, this study provides fundamental information about the performance of Sentinel-2 LAI, FAPAR, and FVC estimates, which imbues our confidence in the broad applications of these decametric products.

Details

Language :
English
ISSN :
20724292
Volume :
12
Issue :
6
Database :
Directory of Open Access Journals
Journal :
Remote Sensing
Publication Type :
Academic Journal
Accession number :
edsdoj.6a4b322570b4dcda054983f7579f703
Document Type :
article
Full Text :
https://doi.org/10.3390/rs12060912