Validation and clinical application of a targeted next-generation sequencing gene panel for solid and hematologic malignancies

Authors :
Iván Prieto-Potin
Nerea Carvajal
Jenifer Plaza-Sánchez
Rebeca Manso
Carmen Laura Aúz-Alexandre
Cristina Chamizo
Sandra Zazo
Almudena López-Sánchez
Socorro María Rodríguez-Pinilla
Laura Camacho
Raquel Longarón
Beatriz Bellosillo
Rosa Somoza
Javier Hernández-Losa
Víctor Manuel Fernández-Soria
Ricardo Ramos-Ruiz
Ion Cristóbal
Jesús García-Foncillas
Federico Rojo
Source :
PeerJ, Vol 8, p e10069 (2020)
Publication Year :
2020
Publisher :
PeerJ Inc., 2020.

Abstract

Background Next-generation sequencing (NGS) is a high-throughput technology that has become widely integrated in molecular diagnostics laboratories. Among the large diversity of NGS-based panels, the Trusight Tumor 26 (TsT26) enables the detection of low-frequency variants across 26 genes using the MiSeq platform. Methods We describe the inter-laboratory validation and subsequent clinical application of the panel in 399 patients presenting a range of tumor types, including gastrointestinal (GI, 29%), hematologic (18%), lung (13%), gynecological and breast (8% each), among others. Results The panel is highly accurate with a test sensitivity of 92%, and demonstrated high specificity and positive predictive values (95% and 96%, respectively). Sequencing testing was successful in two-thirds of patients, while the remaining third failed due to unsuccessful quality-control filtering. Most detected variants were observed in the TP53 (28%), KRAS (16%), APC (10%) and PIK3CA (8%) genes. Overall, 372 variants were identified, primarily distributed as missense (81%), stop gain (9%) and frameshift (7%) altered sequences and mostly reported as pathogenic (78%) and variants of uncertain significance (19%). Only 14% of patients received targeted treatment based on the variant determined by the panel. The variants most frequently observed in GI and lung tumors were: KRAS c.35G > A (p.G12D), c.35G > T (p.G12V) and c.34G > T (p.G12C). Conclusions Prior panel validation allowed its use in the laboratory daily practice by providing several relevant and potentially targetable variants across multiple tumors. However, this study is limited by high sample inadequacy rate, raising doubts as to continuity in the clinical setting.

Details

Language :
English
ISSN :
21678359
Volume :
8
Database :
Directory of Open Access Journals
Journal :
PeerJ
Publication Type :
Academic Journal
Accession number :
edsdoj.6a82bc40e8c845f88d8f03973d27e115
Document Type :
article
Full Text :
https://doi.org/10.7717/peerj.10069