Back to Search Start Over

Active contour configuration model for estimating the posterior ablative margin in image fusion of real-time ultrasound and 3D ultrasound or magnetic resonance images for radiofrequency ablation: an experimental study

Authors :
Junkyo Lee
Min Woo Lee
Dongil Choi
Dong Ik Cha
Sunyoung Lee
Tae Wook Kang
Jehoon Yang
Jaemoon Jo
Won-Chul Bang
Jongsik Kim
Dongkuk Shin
Source :
Ultrasonography, Vol 37, Iss 4, Pp 337-344 (2018)
Publication Year :
2018
Publisher :
Korean Society of Ultrasound in Medicine, 2018.

Abstract

Purpose The purpose of this study was to evaluate the accuracy of an active contour model for estimating the posterior ablative margin in images obtained by the fusion of real-time ultrasonography (US) and 3-dimensional (3D) US or magnetic resonance (MR) images of an experimental tumor model for radiofrequency ablation. Methods Chickpeas (n=12) and bovine rump meat (n=12) were used as an experimental tumor model. Grayscale 3D US and T1-weighted MR images were pre-acquired for use as reference datasets. US and MR/3D US fusion was performed for one group (n=4), and US and 3D US fusion only (n=8) was performed for the other group. Half of the models in each group were completely ablated, while the other half were incompletely ablated. Hyperechoic ablation areas were extracted using an active contour model from real-time US images, and the posterior margin of the ablation zone was estimated from the anterior margin. After the experiments, the ablated pieces of bovine rump meat were cut along the electrode path and the cut planes were photographed. The US images with the estimated posterior margin were compared with the photographs and post-ablation MR images. The extracted contours of the ablation zones from 12 US fusion videos and post-ablation MR images were also matched. Results In the four models fused under real-time US with MR/3D US, compression from the transducer and the insertion of an electrode resulted in misregistration between the real-time US and MR images, making the estimation of the ablation zones less accurate than was achieved through fusion between real-time US and 3D US. Eight of the 12 post-ablation 3D US images were graded as good when compared with the sectioned specimens, and 10 of the 12 were graded as good in a comparison with nicotinamide adenine dinucleotide staining and histopathologic results. Conclusion Estimating the posterior ablative margin using an active contour model is a feasible way of predicting the ablation area, and US/3D US fusion was more accurate than US/MR fusion.

Details

Language :
English
ISSN :
22885919 and 22885943
Volume :
37
Issue :
4
Database :
Directory of Open Access Journals
Journal :
Ultrasonography
Publication Type :
Academic Journal
Accession number :
edsdoj.6c0043390a1447d5903889e794e2038a
Document Type :
article
Full Text :
https://doi.org/10.14366/usg.17065